Hubei, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Consumer Electronics, Electrical & Electronics, Industrial Equipment & Components, ...
Management System Certification:
ISO 9001
Main Markets:
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, ...
OEM/ODM Availability:
Yes
OEM/ODM Service
Overseas Agent / Branch

Secondary Current Injection, Monophasic Tester, Monophasic Protection Tester manufacturer / supplier in China, offering 180A Relay Protection Tester (single phase), Vlf High Voltage Generator 60kv, Breakdown Voltage Tester 80kv and so on.

Gold Member Since 2012
Audited Supplier
  • 180A Relay Protection Tester (single phase)
  • 180A Relay Protection Tester (single phase)
  • 180A Relay Protection Tester (single phase)
  • 180A Relay Protection Tester (single phase)
  • 180A Relay Protection Tester (single phase)
  • 180A Relay Protection Tester (single phase)

180A Relay Protection Tester (single phase)

Get Latest Price
Min. Order: 1 Piece
Port: Wuhan, China
Production Capacity: 20 Sets/Month
Payment Terms: L/C, T/T, Western Union, Paypal, Money Gram
Transport Package: Plywood Case
Specification: CE mark
Trademark: GOLDSOL
Origin: China

You Might Also Like

Loading...

Basic Info

Model NO.: JBC-III
HS Code: 903033200

Product Description

I. Overview

Relay protection tester is significant instrument of calibration and commissioning used for relay protection circuit and instrument of power generation, supply and consumption equipments in the power system and large plant and mining enterprises.

This instrument is composed of digital millisecond meter with fully-isolating dual channels and long time counting, large power AC and DC voltage, current output unit, high-precision multifunctional AC/DC digital ammeter and voltmeter, and logic control, overload protection and signal display unit with very strong functions; adds the power frequency phase meter and automatic reclosing test function.

The two input channels of millisecond meter are provided with complete electric isolation, without considering common-ground short-circuiting during the test, and it is particularly suitable for online electrical testing of dynamic characteristics of the relay. This is not in common relay protection tester and millisecond meter. The dual-channel signal can be made with idle contact. Positive (negative) pulse, test power source, automatic synchronization signal and positive (negative) pulse width can meet the time characteristic test and whole-set test for various relays. The phase meter is more suitable for the testing of complex protection. All the measured values are displayed in digital manner, which are intuitive and precise. This relay is a new-generation tool for protection checking.

180A Relay Protection Tester (single phase)

II. Technical paremeters

(I) Digital millisecond meter
1. Range: 99.9999S
2. Resolution: 0.1ms
3. Accuracy: ±0.001%±1digit
4. Measurement functions:
1) Positive and negative pulse width
2) With the breaking (making) of idle contact, positive (negative) pulse and circuit interruption (supply) of electricity, double-channel input can constitute 6×4=24 functions (Table 2 and 3 list the commonly used combinations).
5. The isolation voltage between two channels is bigger than 250VDC, 250VAC and the peak value is 354V.

Table 1 Shift gear table of input signal amplitude
Input signal amplitude (V)5-1515-4040-120120-250
Trigger voltage (V)2.5±20%7.5±25%20±25%60±25%
Reliable and non-operating voltage (V)241648

6. Input reactance ≥200KΩ
7. Refer to Table 1 for input signal range

180A Relay Protection Tester (single phase)

(II) Digital phase meter

1. Scope of measurement: 360.0 degrees
2. Resolution: 0.1 degree
3. Accuracy: <±1%±1 character for input signal voltage ≥150mV, current ≥15mA
<1.5%±1 character for input signal voltage ≥50mV, current 50mA

(III) Digital voltmeter:
AC and DC voltage,  digit display, maximum resolution 0.1V, accuracy 0.5%±1 character

(IV) Digital ammeter:
AC and DC current,  digit display, resolution 0.1A, accuracy 0.5%±1 character

(V) Power source output:
1. AC voltage: 0~250V, continuously adjustable, maximum output power 1,000VA, with short circuit and      overload protection, and current limit 4A.
2. AC current, 0~130A continuously adjustable, maximum output power 1,200VA, with short circuit and overload  protection, and current limit 180A.
3. DC voltage output: 0-250V, continuously adjustable, with short circuit and overload protection, and  current limit 2.5A.
4. DC fixed voltage 110V or 220V output, which can be outputted with AC voltage 0~250V or DC current     0~130A.
5. DC current output: 0~5A, continuously adjustable with short circuit protection, and current limit 5A

(VI) Others
1. Power source: 220±10%, 50/60Hz;
2. Ambient temperature for use: 0~40ºC, temperature ensuring the precision 15~35ºC;
3. Ambient temperature: 90ºC (25ºC);
4. Volume: 440×260×260;
5. Weight: 15kg;

180A Relay Protection Tester (single phase)


 

Send your message to this supplier

*From:
*To:
avatar Mr. Luo
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now