0.1Hz Vlf Hipot High Voltage Tester with Pd Testing 80kv
Contact Supplier
Product Attributes
- Customization
- Available
- After-sales Service
- Life Time Maintenance
- Warranty
- One Year
- Model NO.
- VLF-80P
- Output Voltage
- 80kv
- Output Frequency
- 0.1Hz-0.01Hz
- Colour
- Black
- Transport Package
- Aluminum Box Inside
- Specification
- CE
- Trademark
- GOLDSOL
- Origin
- China
- HS Code
- 9030390009
- Production Capacity
- 20 Units/Month
- Package Size
- 40.00cm * 50.00cm * 60.00cm
- Package Gross Weight
- 60.000kg
Shipping
- Shipping Cost:
- Contact the supplier about freight and estimated delivery time.
Online Trading Protection
- Payment Guarantee
-
Platform-protected payments with refund support for eligible order issues.
- Platform Logistics
- Clearer shipment tracking with platform-supported logistics.
- Inspection Service
- Optional pre-shipment inspection for quality and quantity checks.
- After-Sales & Dispute Handling
- Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Product Images of 0.1Hz Vlf Hipot High Voltage Tester with Pd Testing 80kv
Find Similar Products
Product Description
The "VLF-P" series supply AC withstand voltage testing + PD(pc) + Capacity(μF).
-Micro-controller
-Advanced digital frequency technology
-Built-in printer
-Discharge free
-Portable
-60mins Continous working
-CE mark
-Patent
-5th generation
AC withstand voltage testing
DC withstand voltage testing
VLF Advantage
8. H/L voltage closed loop negative feedback control circuit, output no capacity rise effect.
9. Built-in printer.
10. Built-in protective resistors.
11. Colour Touch LCD (154*86mm)operation, True sine wave output.
12. Real-time display of actual output waveform.
13. Ergonomic, menu guided, large colour touch screen
14. Storage of test results for later retrieval and print.
15. Over voltage and current protected.
16.Auto variable frequency 0.1Hz, 0.05Hz, 0.02 Hz, 0.01 Hz.
17. 60 mins continuous working;
18. Data of current, voltage and waveform directly sampled at HV side.
19. Rugged and reliable design less prone to failure from transients.
20. Invatation Patent
21. Portable: Control unit + Booster (Tank)
22. CE mark.
23. RS232 for option.
24. Remote control system for option
Specification
1.Power: 220V ± 10% AC (110V can be customized), 50/60Hz, single phase;
2.Output-Voltage (Peak): 1 to rated value (KV), details see the below table;
3.Output frequency: 0.1Hz, 0.05Hz, 0.02 Hz, 0.01 Hz (auto variable frequency);
4.Load: 0.5μF (approx 6,000 ft of cable) @ 0.1 Hz
1.0μF (approx 12,000 ft of cable) @ 0.05 Hz
2.5μF (approx 30,000 ft of cable) @ 0.02 Hz
5.0μF (approx 60,000 ft of cable) @ 0.01 Hz
5. Stability of frequency: Fluctuation < 0.5%;
6. Measurement accuracy: ±3%;
7. Positive and negative voltage peak error: ≤3%;
8. Voltage waveform distortion: ≤5%;
9. Construction: 1 Control unit + 1 Booster (≤60KV set); 1 Control unit + 2 Boosters(≥60KV set).
10. Ambient conditions of use: temperature Indoor and outdoor : -10ºC ~ + 50ºC.
11. Humidity:≤85%
12. Technical indexes of VLF tgδ test (for option):
1) tgδ test voltage range: 1 to 40KV (Only one booster can be used for tan delta test if 2 boosters set)
2) Measurement voltage accuracy: 3%
3) Dielectric loss test frequency: 0.1Hz
4) Measurement range: 0.01×10-3- 655.35×10-3
5) Dielectric loss accuracy: 1x10-4
6) Dielectric loss resolution: 1x10-5
7) Capacitance measurement range: 0.001μF-10μF
8) Celectric capacity resolution: 0.001μF
9) Current measurement range: 0-59mA
10) Current resolution: 0.1mA
11) Insulation resistance: 0.01GΩ-65.53GΩ
12) Insulation resistance resolution: 10MΩ
13.Main technical indexes of VLF PD test :
1) Partial discharge measurement range: 0.01pc-5000pc
2) Partial discharge detection sensitivity: 0.01pc
3) Capacitance range: 0.001μF-10μF
4) Sampling bits: 12 bits
5) Sampling speed: 200M/S
6) Test voltage: 0 to rated value (KV)
14.DC leakage current measurement (for option):
1) Output rated voltage: same as rated AC voltage output
2) Voltage accuracy: 3%
3) Leakage current range: 0-2000μA
4) DC Current resolution: 1μA
5) DC current accuracy: 3%
6) It is necessary to parallel the capacitor we supplied if testing DC leakage current.
Model no |
Output Voltage/ Current (Peak) |
Load Capacity | Control Unit | Booster(Tank) | Power | ||
| Capacitance/ Freuency |
Net Dim. (cm) |
Net Wt (kg) |
Net Dim. (cm) |
Net Wt (kg) |
|||
| VLF-30P | 30KV/20mA | 0.1Hz-0.01Hz Auto Variable Capacity:≤10µF |
40×31×20 | 6 | 29x15×35 | 25 | 1000W |
| VLF-40P | 40KV/20mA | 0.1Hz-0.01Hz Auto Variable Capacity:≤10µF |
40×31×20 | 6 | 29x15×35 | 25 | 1200W |
| VLF-50P | 50KV/30mA | 0.1Hz-0.01Hz Auto Variable Capacity:≤10µF |
40×31×20 | 6 | 45×19×36 | 45 | 1500W |
| VLF-60P | 60KV/59mA | 0.1Hz-0.01Hz Auto Variable Capacity:≤5µF at 60KV; |
40×31×20 | 6 | 45×19×36 |
45 | 2000W |
| VLF-80P | 80KV/59mA | 0.1Hz-0.01Hz Auto Variable Capacity:≤5µF at 80KV; Capacity:≤10µF for single booster (40/40KV) |
40×31×20 |
6 | 29x15×35 | 25 | 3000W |
| 36x19×45 | 45 | ||||||
| VLF-90P | 90KV/59mA | 0.1Hz-0.01Hz Auto Variable Capacity:≤5µF at 90KV; Capacity:≤10µF for single booster (40/50KV) |
40×31×20 |
6 | 29x15×35 | 25 | 3500W |
| 36x19×45 | 45 | ||||||
Field connection diagram (Test object: cable)
True LCD screenshoot test results
Function comparison of VLF series models
| Output (Peak) |
Structure | Model no | AC Withstand Voltage Test | Tan Delta Test | PD Test | Capacity (μF) |
Insulation Resistance Test (IR) |
30KV |
1*Controller 1*30KV Booster 1*Capacitor |
VLF-30 | √ | X | X | X | X |
| VLF-30T | √ | √ | X | √ | √ | ||
| VLF-30P | √ | X | √ | √ | X | ||
| VLF-30M | √ | √ | √ | √ | √ | ||
40KV |
1*Controller 1*40KV Booster 1*Capacitor |
VLF-40 | √ | X | X | X | X |
| VLF-40T | √ | √ | X | √ | √ | ||
| VLF-40P | √ | X | √ | √ | X | ||
| VLF-40M | √ | √ | √ | √ | √ | ||
50KV |
1*Controller 1*50KV Booster 1*Capacitor |
VLF-50 | √ | X | X | X | X |
| VLF-50T | √ | √ | X | √ | √ | ||
| VLF-50P | √ | X | √ | √ | X | ||
| VLF-50M | √ | √ | √ | √ | √ | ||
60KV |
1*Controller 1*60KV Booster 1*Capacitor |
VLF-60 | √ | X | X | X | X |
| VLF-60T | √ | √ | X | √ | √ | ||
| VLF-60P | √ | X | √ | √ | X | ||
| VLF-60M | √ | √ | √ | √ | √ | ||
70KV |
1*Controller 1*30KV Booster 1*40KV Booster 1*Capacitor |
VLF-70 | √ | X | X | X | X |
| VLF-70P | √ | X | √ | √ | X | ||
80KV |
1*Controller 1*30KV Booster 1*50KV Booster 1*Capacitor, or 1*Controller 2*40KV Booster 1*Capacitor |
VLF-80 | √ | X | X | X | X |
| VLF-80T | √ | √ | X | √ | √ | ||
| VLF-80P | √ | X | √ | √ | X | ||
| VLF-80M | √ | √ | √ | √ | √ | ||
90KV |
1*Controller 1*40KV Booster 1*50KV Booster 1*Capacitor |
VLF-90 | √ | X | X | X | X |
| VLF-90T | √ | √ | X | √ | √ | ||
| VLF-90P | √ | X | √ | √ | X | ||
| VLF-90M | √ | √ | √ | √ | √ | ||
| Note: DC leakage current measurement for buyer's option (any type can add this function if required). | |||||||
Package for transport :
| Sr no | Name of Commodity | Qty | N.W | G.W | Transport size (LxWxH) |
1 |
Controller | 1 unit | 5 kg | 52 kg |
450x380x800mm |
| Capacitor 0.04µF | 1 unit | 5 kg | |||
| Booster I (30/40KV) | 1 unit | 25 kg | |||
| Aluminum alloy box | 1 unit | 5kg | |||
| Total: | 1 set | 40 kg | 52 kg | 0.14 m3 | |
| Packed in 1 wooden case. | |||||
2) 50KV/60KV test set:
| Sr no | Name of Commodity | Qty | N.W | G.W | Transport size (LxWxH) |
1 |
Controller | 1 unit | 5 kg | 80 kg |
470x430x950mm |
| Capacitor 0.04µF | 1 unit | 5 kg | |||
| Booster I (50/60KV) | 1 unit | 45 kg | |||
| Aluminum alloy box | 1 unit | 5kg | |||
| Total: | 1 set | 60 kg | 80 kg | 0.19 m3 | |
| Packed in 1 wooden case. | |||||
| Sr no | Name of Commodity | Qty | N.W | G.W | Transport size (LxWxH) |
1 |
Controller | 1 unit | 5 kg | 52 kg |
450x380x800mm |
| Capacitor 0.04µF | 1 unit | 5 kg | |||
| Booster I (30/40KV) | 1 unit | 25 kg | |||
| Aluminum alloy box | 1 unit | 5kg | |||
| 2 | Booster II (40/50KV) | 1 unit | 45 kg | 69 kg | 470x430x720mm |
| Aluminum alloy box | 1 unit | 6 kg | |||
| Total: | 1 set | 91 kg | 121 kg | 0.29 m3 | |
| Packed in 2 wooden cases. | |||||
Accessories
| Sr no. | Description | Quantity | Remarks | |
| 1 | Control unit | 1 | unit | |
| 2 | Booster I (Tank I) | 1 | unit | 1 Booster if ≤60KV set; 2 boosters for ≥70KV set. |
| Booster II (Tank II) | 1 | unit | ||
| 3 | Capacitor (0.04µF) | 1 | unit | Used as Capacity supplement, or test object for demo |
| 4 | Discharge rod | 1 | unit | |
| 5 | HV Test/Connection cables | 1 | set | |
| 6 | Earth cable | 1 | unit | |
| 7 | Power supply cable | 1 | unit | |
| 8 | Fuse | 2 | units | |
| 9 | Printer paper | 1 | unit | |
| 10 | Operating manual | 1 | unit | |
| 11 | Aluminium alloy box | 1 | unit | 1 aluminium alloy box ≤60KV set; 2 aluminium alloy boxes ≥70KV set. |
| 1 | unit | |||
| 12 | Calibration report | 1 | unit | |
About the Supplier
Company Profile
GOLDSOL(WUHAN) HIPOT TEST EQUIPMENT FACTORY
(Wuhan Goldsol Co., Ltd) is the manufacturer and trade company with 78 employees; It was established in 2001, located in No. 39 Hongyi Industrial Park, Hanshi Road, Wuhan China. The factory occupy an area of 1763 square meters.
GOLDSOL have obtained CE certificates for VLF Hipot Tester, AC/DC Hipot Tester, Primary & seconday current Injection, CT/PT Tester, Oil Tester, Tan Delta Tester, Circuit Breaker Analyzer, Micro-ohmmeter, High voltage divider, Transformer Ratio Tester, Insulation Resistance Tester.
GOLDSOL has successfully foreign trading experience in Europe, Southeast, Mideast, Africa, South America and Oceania.
The factory was backed by fine credit, technological advantages, excellent products and complete after-sales services.
The VLF (Very Low Frequency) Hipot Tester is the new development product, the production has got the State Patent of Invention (SN No. 200710152385-Ultra low frequency high-pressure generator).
The factory has been audited by the SGS & BV Group, You're welcomed to contact us for more information!
About Our Factory & Business Background
- Address
- Room 507, Unit 1, Building 1, Optical Valley, Tanhu 1st Road, Canglong Island, Jiangxia District, Wuhan China
- Terms of Payment
- LC, T/T, PayPal, Western Union, Small-amount payment, Money Gram
- International Commercial Terms(Incoterms)
- FOB, CFR, CIF, DAT, FAS, DDP, DAP, CPT, FCA, EXW
- Average Lead Time
-
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays - Nearest Port
- Wuhan/Shanghai/Shenzhen/Guangzhou
Our Production Capability & Technical Expertise
Our Industry Experience & Global Business Record
- Export Year
- 2006-05-10
- Main Markets
- North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
Send your message to this supplier
People who viewed this also viewed
-
US$6,000.00-26,000.00 / Piece
-
US$5,000.00-8,000.00 / Piece
-
US$500.00-700.00 / Piece
-
US$8,000.00-15,000.00 / set
-
US$1,200.00-2,500.00 / set
-
US$8,000.00-15,000.00 / set
-
US$1,500.00-2,500.00 / Piece
-
US$2,000.00-20,000.00 / Piece
-
US$900.00-1,200.00 / Piece
-
US$2,000.00-20,000.00 / Piece
Product Groups
- Other testing
- Cable fault tester
- High Voltage Divider (Kilovoltmeter)
- Primary current injection testing
- AC Withstand voltage testing
- SF6 Gas Testing
- Circuit Breaker Testing
- Relay Protection testing
- Transformer Oil Testing
- DC Withstand Voltage Testing
- Transformer Testing
- VLF Insulation Withstand Voltage Testing
Find Similar Products By Category
- Supplier Homepage
- Products
- VLF Insulation Withstand Voltage Testing
- VLF PD testing (VLF-P series)
- 0.1Hz Vlf Hipot High Voltage Tester with Pd Testing 80kv
Related Categories
Hot Searches
- Testing Machine Factories
- Testing Equipment Factories
- Material Testing
- Function Testing Factories
- Automatic Testing Tester
- Tensile Testing Tester
- Spray Testing Tester
- Hipot Test
- Hipot Test Machine
- Hipot Test Set Bulkbuy