Secured Trading Service

Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics

GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
  • Audited Supplier
  • 15 yrs

Contact Supplier

Product Highlights

  • Lifetime Maintenance: Provides life time maintenance service for the equipment.
  • One Year Warranty: Includes a comprehensive one year warranty coverage.
  • Multi-Function Testing: Performs VLF AC/DC Hipot, Tan Delta, PD, and IR tests.
  • Customizable Voltage: 110V power supply is available as a customized option.
  • Advanced Frequency Tech: Features auto variable frequency from 0.01Hz to 0.1Hz.
  • Portable Design: Compact unit for 30-60KV; 2 units for 80KV applications.
  • IP67 Waterproof: Rugged design ensures reliability in indoor and outdoor use.
  • Touch LCD Operation: Ergonomic 154*86mm color touch screen for easy control.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics

Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics
Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics pictures & photos
Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics
Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics pictures & photos
Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics
Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics pictures & photos
Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics
Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics pictures & photos
Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics
Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics pictures & photos
Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics
Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics pictures & photos
Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics
  • Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics
  • Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics
    Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics
  • Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics
    Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics
  • Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics
    Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics
  • Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics
    Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics
  • Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics
    Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics
  • Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics
    Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics

Find Similar Products

Product Description

VLF (Very Low Frequency) Hipot Testers are suitable for testing power cables, transformers, switchgear, rotating machinery and other electrical apparatus.

For buyer's option:
1.Tan dleta (tgδ) test + Capacity(μF) + IR(Ω)
2."IEE 400.2" Analysis of Tan delta test result
3.Partial discharge PD(pc) testing
4.DC withstand voltage test (leakage current display)


-Micro-controller
-Advanced digital frequency technology
-Built-in printer
-Discharge free
-Portable
-60mins Continous working
-CE mark
-Patent
-5th generation

VLF Advantage

1.AC Withstand voltage testing, Voltage & current curve display.
2.Tan delta (tgδ test), capacitance (μF) and IR (ohm) Test without external device.
3.Partial discharge testing without external device (for buyer's option).
4.DC withstandi voltage test,DC leakage current measurement (for buyer's option).
5."IEE 400.2" Analysis of Tan delta test result.
6.Safe Optical isolation technology.
7. Easiest to use Fully automatic microcontroller.
8. H/L voltage closed loop negative feedback control circuit, output no capacity rise effect.
9. Built-in printer.
10. Built-in protective resistors.                               
11. Colour Touch LCD (154*86mm)operation, True sine wave output.
12. Real-time display of actual output waveform.        
13. Ergonomic, menu guided, large colour touch screen
14. Storage of test results 99 groups for later retrieval and print.                        
15. Over voltage and current protected.
16.Auto variable frequency 0.1Hz, 0.05Hz, 0.02 Hz, 0.01 Hz.
17. 60 mins continuous working;
18. Data of current, voltage and waveform directly sampled at HV side.
19. IP67 waterproof rugged and reliable design.
20. Invatation Patent                                                    
21. Portable: only one unit for 30KV/40KV/50KV/60KV, 2 units for 80KV (Control unit + Tank).
22. CE mark.
23. RS232/USB (for buyer's option).

Vlf AC/DC Hipot High Voltage Tester with Pd & Tangent Diagnostics

Specification
1.Power: 220V ± 10% AC (110V can be customized), 50/60Hz, single phase;
2.Output-Voltage (Peak): 1 to rated value (KV);
3.Output frequency: 0.1Hz, 0.05Hz, 0.02 Hz, 0.01 Hz (auto variable frequency);
4.Load: 0.5μF (approx 6,000 ft of cable)  @ 0.1 Hz 
         1.0μF (approx 12,000 ft of cable) @ 0.05 Hz 
         2.5μF (approx 30,000 ft of cable) @ 0.02 Hz 
         5.0μF (approx 60,000 ft of cable) @ 0.01 Hz 
5. Stability of frequency: Fluctuation < 0.5%;
6. Measurement accuracy: ±3%;
7. Positive and negative voltage peak error: ≤3%;                              
8. Voltage waveform distortion: ≤5%;                                  
9. Construction: only one unit for 40KV;  2 units for 80KV(1 Control unit +1 Tank).
10. Ambient conditions of use: temperature Indoor and outdoor : -10ºC ~ + 50ºC.          
11. Humidity:≤85%       

Model no
Output
Voltage
(AC/DC)

Output current
Load Capacity Fuse

Structure
Capacitance/
Frequency
 
VLF-30TD 1~30KV
AC: 20mA
DC: 2000μA
Auto/manual Frequency:0.1Hz-0.01Hz
Capacity≤10µF
(1.0µF@0.1Hz/30KV)
10A Integrated device:35kg
1 Capacior: 3kg
VLF-40TD 1~40KV
AC: 20mA
DC: 2000μA
Auto/manual
Frequency:0.1Hz-0.01Hz
Capacity≤10µF
(1.0µF@0.1Hz/40KV)
15A Integrated device:35kg
1 Capacior: 3kg
VLF-50TD 1~50KV
AC: 30mA
DC: 2000μA
Auto/manual Frequency:0.1Hz-0.01Hz
Capacity≤10µF
(1.0µF@0.1Hz/50KV)
20A Integrated device:40kg
1 Capacior: 4.2kg
VLF-60TD 1~60KV
AC: 59mA
DC: 2000μA
Auto/manual Frequency:0.1Hz-0.01Hz
Capacity≤5µF
(0.5µF@0.1Hz/60KV)
20A Integrated device:40kg
1 Capacior: 4.2kg
VLF-70TD 1~70KV
AC: 59mA
DC: 2000μA
Auto/manual Frequency:0.1Hz-0.01Hz
Capacity≤5µF at 70KV;
≤10µF at 50KV
(0.5µF@0.1Hz/70KV)
30A Control part:35kg
(Controller+1*30KV tank)
1*40KV tank: 45kg
1 Capacior: 4.2kg
VLF-80TD 1~80KV
AC: 59mA
DC: 2000μA
Auto/manual Frequency:0.1Hz-0.01Hz
Capacity≤4µF at 80KV
≤10µF at 50KV
(0.4µF@0.1Hz/80KV)
30A Control part:35kg
(Controller+1*40KV tank)
1*40KV tank: 45kg
1 Capacior: 4.2kg
Note: DC leakage current measurement for buyer's option.
 
Vlf AC/DC Hipot High Voltage Tester with Pd &amp; Tangent Diagnostics 

12. Technical indexes of VLF tgδ test:
  1) tgδ test voltage range: 1 to 40KV;
  2) Measurement voltage accuracy: 3%
  3) Dielectric loss test frequency: 0.1Hz
  4) Measurement range: 0.01×10-3- 655.35×10-3
  5) Dielectric loss accuracy: 1x10-4
  6) Dielectric loss resolution: 1x10-5
  7) Capacitance measurement range: 0.001μF-10μF
  8) Celectric capacity resolution: 0.001μF                     
  9) Current measurement range: 0-59mA                       
  10) Current resolution: 0.1mA
  11) Insulation resistance: 0.01GΩ-65.53GΩ
  12) Insulation resistance resolution: 10MΩ

Vlf AC/DC Hipot High Voltage Tester with Pd &amp; Tangent Diagnostics
Vlf AC/DC Hipot High Voltage Tester with Pd &amp; Tangent Diagnostics
Vlf AC/DC Hipot High Voltage Tester with Pd &amp; Tangent Diagnostics
Vlf AC/DC Hipot High Voltage Tester with Pd &amp; Tangent Diagnostics
Vlf AC/DC Hipot High Voltage Tester with Pd &amp; Tangent Diagnostics

Analysis of Tan delta test results (IEE400.2)
Vlf AC/DC Hipot High Voltage Tester with Pd &amp; Tangent Diagnostics
13.
Main technical indexes of VLF PD test (for option):

  1) Partial discharge measurement range: 0.01pc-200pc
  2) Partial discharge detection sensitivity: 0.01pc
  3) Capacitance range: 0.001μF-10μF
  4) Sampling bits: 12 bits
  5) Sampling speed: 12M/S                                        
  6) Test voltage:  0 to rated value (KV)
Vlf AC/DC Hipot High Voltage Tester with Pd &amp; Tangent Diagnostics
14.DC leakage current measurement (for option):
  1) Output rated voltage: same as rated AC voltage output
  2) Voltage accuracy: 3%
  3) Leakage current range: 0-2000μA
  4) DC Current resolution: 1μA
  5) DC current accuracy: 3%
  6) It is necessary to parallel the capacitor we supplied if testing DC leakage current.

Field connection diagram
 Vlf AC/DC Hipot High Voltage Tester with Pd &amp; Tangent Diagnostics     It gives 80KV output when external connecting 40KV tank.
              
Package for transport

1) 40KV test set:
Sr no  Name of Commodity  Qty  N.W  G.W Transport size
(LxWxH)
1 40KV test set
Including 1 capacitor and 1 wires case
1 unit 46 kg 80 kg 580x400x500mm
                     Total: 1 set 46 kg 80 kg 0.19 m3
                                                        Packed in 1 wooden case.
 
 2) 80KV test set:
Sr no  Name of Commodity  Qty  N.W  G.W Transport size
(LxWxH)
1 Controll part 1 unit 45 kg 50 kg 550x400x500mm
2 Tank 1 unit 45 kg 69 kg 470x430x720mm
Capacitor 1 unit 4 kg
Aluminum alloy box   1 unit 6 kg
 
                     Total: 1 set 90 kg 119 kg 0.26 m3
                                                       Packed in 2 wooden cases.

Vlf AC/DC Hipot High Voltage Tester with Pd &amp; Tangent Diagnostics
Accessories
Sr no.      Description Quantity Remarks
  1 Control part 1 unit  
  2 Booster  (Tank) 1 unit No external tank for 30KV,40KV,50KV, 60KV
  3 Capacitor (0.04µF) 1 unit Used as Capacity supplement, or test object for demo
  4 Discharge rod 1 unit  
  5 HV Test/Connection cables 1 set  
  6 Earth cable 1 unit  
  7 Power supply cable 1 unit  
  8 Fuse 2 units  
  9 Printer paper 1 unit  
 10 Operating manual 1 unit  
 11 Aluminium alloy box 1 unit  
 12 Calibration report 1 unit  


Vlf AC/DC Hipot High Voltage Tester with Pd &amp; Tangent Diagnostics

About the Supplier

Watch Video
Watch Video
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY

About Our Factory & Business Background

Address
Room 507, Unit 1, Building 1, Optical Valley, Tanhu 1st Road, Canglong Island, Jiangxia District, Wuhan China
Terms of Payment
LC, T/T, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, CFR, CIF, DAT, FAS, DDP, DAP, CPT, FCA, EXW
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Wuhan/Shanghai/Shenzhen/Guangzhou

Our Production Capability & Technical Expertise

Main Products
Vlf Hipot Testers, AC Hipot Tester, DC Hipot Tester, Resonant Test Set, Micro Ohmmeter, Tan Delta Tester, Primary Current Injection, Secondary Current Injection, CT PT Analyzer, Circuit Breaker Analyzer

Our Industry Experience & Global Business Record

Export Year
2006-05-10
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the warranty period?
We provide a one year warranty for all our equipment.
Is the power supply voltage customizable?
Yes, the 110V power supply is available as a customized option.
What testing functions does this device support?
It supports VLF AC/DC Hipot, Tan Delta, Partial Discharge, and Insulation Resistance testing.
How long is the lead time for orders?
The average lead time is within 15 workdays for both peak and off-peak seasons.
What is the maximum output voltage?
The device supports output voltages up to 80KV, requiring two units for the 80KV model.
Is the device suitable for outdoor use?
Yes, it features an IP67 waterproof design and operates in temperatures from -10 to +50 degrees Celsius.
What payment methods are accepted?
We accept LC, T/T, PayPal, Western Union, Small-amount payment, and Money Gram.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

People who viewed this also viewed