| Sr no |
Description |
Specfication |
Qty |
| 1 |
Impulse voltage geneartor (Main body) |
|
|
| 1.1 |
Main capacitor |
1.0uF/100kV |
2 unit |
| 1.2 |
Modulation resistor |
20Ω~200Ω;1kΩ~3kΩ |
4 group |
| 1.3 |
Charging resistor |
20kΩ |
1 set |
| 1.4 |
Discharge ball gap |
Ф150mm |
2 pairs |
| 1.5 |
Pulse ignition device and ball distance adjusting mechanism |
15kV |
1 set |
| 1.6 |
Insulating support & material |
|
1 set |
| 1.7 |
High voltage connection board and mobile base |
|
1 set |
| 1.8 |
Ignition check and feedback signal device |
100kV |
1 set |
| 2 |
High voltage discharge earth rod |
|
|
| 2.1 |
Discharge earth rod and accessories |
200kV |
1 pc |
| 3 |
Lightning impulse capacitor voltage divider |
|
|
| 3.1 |
Weak damping impulse capacitive voltage divider |
200kV/200pF,1.0% |
1 unit |
| 4 |
Automatic charging power supply |
|
|
| 4.1 |
Charging transformer |
50kV,5kVA |
1 unit |
| 4.2 |
Multi-voltage capacitor |
50kV,0.1uF |
1 unit |
| 4.3 |
High voltage rectifier stack |
150kV,200mA |
2 pc |
| 4.4 |
Electric grounding protection |
Electric drive mechanism |
1 set |
| 4.5 |
Charging protection resistor on the side of high voltage & low voltage |
Charging protection and charging monitoring |
1 set |
| 5 |
Automatic lightning impulse control system |
|
|
| 5.1 |
Lightining impulse control software |
|
1 set |
| 5.2 |
Auto impulse control |
|
1 pc |
| 5.3 |
Optical fiber conversion transmission circuit and optical fiber |
|
1 set |
| 5.4 |
IPM-24-PLC |
Import product |
1 set |
| 5.5 |
Desktop computer |
|
1 set |
| 6 |
Automatic lightning impulse measurement and analysis system |
|
1 set |
| 6.1 |
TDS3012C High voltage color digital oscilloscope
|
2 channels Accuracy 3%, Record length:10k byte |
1 unit |
| 6.2 |
Secondary attenuator |
100 times |
2 pc |
| 6.3 |
Measuring cable |
20m,75Ω |
2 pcs |
| 6.4 |
Isolattion filter power supply |
10kV |
1 set |
| 6.5 |
Operation desk |
|
1 set |
| 6.6 |
Special software for shock measurement and analysis |
1.0% |
1 set |
| 7 |
200kV Single ball chopping device * |
Electronic |
1 set |
| 8 |
Damage indication current shunt * |
10KA, 1.0% |
1 set |
| 9 |
Transport and insurance |
Negotiation |
|
| 10 |
Installation and commissioning |
The quotation only includes commissioning & demo at factory. |
|
* Chopping device & damage indication current for buyer's option.
|