DC Pressure High Voltage Hv Hipot Test Sets 120kv

Product Details
Customization: Available
After-sales Service: Life Time Maintenance
Type: Strength Testing Machine
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • DC Pressure High Voltage Hv Hipot Test Sets 120kv
  • DC Pressure High Voltage Hv Hipot Test Sets 120kv
  • DC Pressure High Voltage Hv Hipot Test Sets 120kv
  • DC Pressure High Voltage Hv Hipot Test Sets 120kv
  • DC Pressure High Voltage Hv Hipot Test Sets 120kv
  • DC Pressure High Voltage Hv Hipot Test Sets 120kv
Find Similar Products

Basic Info.

Model NO.
ZGF-120KV/2mA
Power Source
AC220V
Transport Package
Aluminum Box Inside and Plywood Case Outside
Specification
CE
Trademark
GOLDSOL
Origin
China
HS Code
9030339000
Production Capacity
100units/Month

Packaging & Delivery

Package Size
45.00cm * 45.00cm * 70.00cm
Package Gross Weight
35.000kg

Product Description

HF multi-voltage circuit
Pulse-width modulation (PWM)technology
Digital display
High accuracy measurement
Continous adjusting
Safety protection
Portable
CE mark

DC Hipot Test Set are suitable for testing
cables, zinc oxide arresters, transformers,
switchgear,rotating machinery and other
electrical apparatus.

Advantages:
1. Portable at site, light in weight & samll size.
2. Easiest to use.                  
3. 100KHz Pulse-width modulation (PWM) technology.
4. Advanced & durable components.        
5. Digital display.
6. High accuracy resolution: voltage 0.1KV, current 0.1µA.
7. Over voltage and current protection, balance protection.
8. Smooth voltage adjusting at full range.
9. 75%VDC-1mA function,convenient to test Zinc Oxide arrester.
10. Rugged and reliable design less prone to failure from transients
11. CE mark.

I.Introduction

Portable HVDC generator is an important equipment for DC voltage withstand test and leakage current test of HV electrical equipments, cables, surge arresters in electriv industry and power supply departments. ZGF Portable HVDC Generator is developed based on the calibration made by National HV Meterage Station, it accords with the standard "Generation Requirement of Portable HVDC Generator"(ZGF 24003-90)
The new technology, new material and optimal selected components are applied, It has the advantages of high power, small volume, light weight, good performance and high stability.

II.Features
1. High reliabiliy: high frequency voltage multi-doubler reticfier, simple circuit, high overload capability, rare fault, without maintenance.
2. Light weight and Small size. one person can easily carry the set.
3. Perfect seal by metal housing, high mechnical stength. Irs performence will not be influenced by viberation, moisture, dust and meterological condition.
4. Safe, convenience in operation, metal housing grounded. built-in HV terminals.
5. There is no high voltage and low voltage connecter outside, easy connection.
6. Good auto protection function. It can nor be switched on if the HV output knob is not at zero position. Poeration is simplw. It will not cause maloperation and automatically switch off in over voltage and overcurrent case. There is dampong resistor indide.It is not necessary to connect damping resistor outside.
7. Excellent accuracy: The leakage current at HV side is meadured by digital  
meter accuracy: 1uA, range switch is not required, disvharge withstand current measurement function is available at low voltage side, It use precise resistor with good stability to measure high voltage.

III.Technique Index
1. power: AC220V+10%, 50Hz+1%
2. Output voltage indicator accuracy: <1%
3. Output current indicator accuracy: <1%
4. Ripple contain factor: <0.5%
5. 0.75 times output voltage indicator accuracy: <1%, can be locked
  Rating output DC voltage(kV) Rating output DC current(mA) Rating output power(W) Multi-voltage tube(m) Weight
(kg)
ZGF-60 60 2 120 0.5 16
  60 3 180 0.5  
  60 10 600 0.5  
ZGF-80 80 2 160 0.8 20
  80 5 80 0.8  
  80 10 1200 0.8  
ZGF-120 120 2 240 0.8 20
  120 5 600 0.8  
  120 10 1200 0.8  
ZGF-200 200 2 400 1.2 26
  200 5 1000 1.2  
  200 10 2000 1.2  
ZGF-300 300 2 600 1.7 31
  300 5 1500 1.7  
  300 10 3000 1.7  


IV.Controller

ZGF portable DC HV generator mainly includes controller & Multi-voltage tube. The panel of controller is showed as below:
  DC Pressure High Voltage Hv Hipot Test Sets 120kv
1. Power input                               2. Power switch
3. "Power" indicator                      4. "Zero" position indicator
5. "Overvoltage" indicator            6. "Overcurrent" indicator
7. Current display                          8. Voltage display
9. Time relay                                  10.Timing on button
11. 0.75 times voltage display    12. Grounding
13. Signal input                              14. Measuring output
15. "Start" button                           16. Stop button
17. Overvoltage setting                18. Voltage coarse adjusting
19. Voltage fine adjusting             20. 0.75 times voltage locking


V.Multi-voltage tube

DC Pressure High Voltage Hv Hipot Test Sets 120kv
1.Top cap
2.Equalizing ring
3.Multi-voltage tube
4.Base of multi-voltage tube
5.grounding
6.Signal input
7.Measurement output

VI.Operation steps
1. Preparation
Connect the signal input cable socket (13) and measurement output socket (14) of the controller with the cable socket of the voltage doubling device with a special cable. Check its integrity before use. The connecting cable shall be free of short circuit and open circuit; The double pressure cylinder shall be free of condensation; Connect the grounding terminal of the control box with the grounding terminal of the voltage doubling device with copper wire of more than 2.5mm2 and reliably grounded.

2. Installation instructions of water resistanor
1)Before each test, unscrew the end of the water resistanor with air hole, add water to more than 2/3 of the submerged conductive rod, and the end with air hole faces upward.
2) After the test, pour out the water and refill it before the next test.
Note: Dry type current limiting resistor does not need to be filled with water.

3.Voltage setting
(1) Plug in the power line and turn on the power switch (2) of the controller. The voltage display (8), current display (7) and 0.75 times voltage display (11) all show "0" value.
(2) Turn the voltage setting button (17) clockwise to the end, turn the voltage coarse adjustment (18) and voltage fine adjustment (19) counterclockwise to "0" position, and the "0"position indicator (4) is on.
(3) Gently press the "Start" button (15), and the "Power" indicator (3) (red) is on. If the "Start" button (15) is pressed, the red indicator light is not on, indicating that the voltage coarse and fine adjustment is not in the zero position, turn the voltage coarse adjustment knob (18) and fine adjustment knob (19) counterclockwise to the zero position, and the red indicator light (3) will be on.
(4) Turn the voltage coarse adjustment knob (18) clockwise. When the voltage is close to the required voltage value, turn the voltage fine adjustment knob (19) until the required voltage. At this time, the unit of voltage display value is kV and the unit of current display value is mA.
(5) Adjust the voltage setting knob (17) counterclockwise to turn off high voltage. At this time, the red indicator (3) is off and the "overvoltage" indicator (5) is on.
It indicates that the instrument is setted according to the required output voltage, that is, when the output reaches the required voltage value, the high voltage is automatically cut off and overvoltage protection is provided.
Note: If the setting knob is not adjusted, the voltage value can only rise to the setting voltage value each time. If the voltage needs to rise to the rated value, the overvoltage setting knob must be adjusted clockwise to the maximum.

4. Test object
(1) Connect the test object between the high-voltage output terminal and the ground terminal.
(2) Turn on the power switch (2), gently press the "Start" button (15), the "Power" indicator (3) (red) is on, and slowly adjust the voltage coarse adjustment knob (18) and voltage fine adjustment knob (19) for test. During the test, the voltage display (8) indicates the test voltage value, in kV; 0.75 times of voltage display (11) indicates 75% of the test voltage kV; Current display (7) indicates the test current mA.
(3) During the test of the test object, press the 0.75 times voltage display locking button (20), then the 0.75 times voltage display (11) display value is locked, and it is inconvenient to maintain the display value. In this way, it can be conveniently used as the reference voltage in the zinc oxide arrester test.
(4) Press the timing on button (10) at any time to start the time relay (9). When the timing reaches the preset time, the buzzer will give an alarm.
(5) During the test, if the load current exceeds 0-10% of the rated output current of the instrument, the "over-current" indicator (6) is on to protect the over-current and prevent damage to the test object and instrument.
(6) After the test, adjust the voltage coarse adjustment knob (18) and voltage fine adjustment knob (19) counterclockwise. After turning to the zero position, the voltage display meter (8) slowly returns to the zero position, and the "zero position" indicator (4) is on. When the three display meters display zero value, gently press the stop button (16). At this time, the red indicator (3) is off, and then turn off the power switch (2).
When the capacitance of the tested object is very large, after the voltage  
coarse and fine adjustments are adjusted to zero, the output voltage display meter cannot return to zero for a long time, press the stop button (16) first, and then shut down. Then discharge the test object with discharge rod, and then remove the wiring of the test object.

VII.Trouble shooting

No Fault Reason Solve
1 When power switch is turned on, the indicator of the power switch is not on, and there is no display for each meter Poor power contact;
Fuse disconnected
Check incoming power supply and line connection;
Replace fuse
2 The "start" indicator of the control box is on, but high voltage no output The signal output cable has poor contact or open circuit and short circuit Check whether the cable is not reliably connected or has open circuit and short circuit
3 It can boost voltage after startup, but the voltmeter and ammeter have no display The measuring input cable has poor contact or open circuit and short circuit Check whether the cable is not reliably connected or has open circuit and short circuit
4 Cannot switch on
  1. Coarse and fine adjustment potentiometers are not in zero position or damaged

2) There was overvoltage or overcurrent action in the last operation
1) Return to zero or replace the coarse and fine potentiometer

2) Turn off the power switch and turn it on again


VIII. Accessaries

1,Control unit.............................................................................................1
2,HV multivoltage tube (Booster)..............................................................1
3,Power supply cable................................................................................1
4,HV Output cable (Controller to Booster)................................................1 
5,Fuse.......................................................................................................2
6,Discharging rod......................................................................................1
7,Ground wire............................................................................................1
8,Current limiting resistor or water resistor................................................1
9,Microammeter.........................................................................................1
10,Calibration.............................................................................................1
11,Operating instruction.............................................................................1

 