Vlf Hv Hipot High Voltage Tester with Tan Delta Tangent Diagnostics

Product Details
Customization: Available
Certification: ISO9001
Protection: Shock Resistance
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Vlf Hv Hipot High Voltage Tester with Tan Delta Tangent Diagnostics
  • Vlf Hv Hipot High Voltage Tester with Tan Delta Tangent Diagnostics
  • Vlf Hv Hipot High Voltage Tester with Tan Delta Tangent Diagnostics
  • Vlf Hv Hipot High Voltage Tester with Tan Delta Tangent Diagnostics
  • Vlf Hv Hipot High Voltage Tester with Tan Delta Tangent Diagnostics
  • Vlf Hv Hipot High Voltage Tester with Tan Delta Tangent Diagnostics
Find Similar Products

Basic Info.

Model NO.
VLF-80TD
Housing
IP67
Transport Package
Aluminum Box Inside and Plywood Case Outside
Specification
CE
Trademark
GOLDSOL
Origin
China
HS Code
903033900
Production Capacity
100units/Month

Packaging & Delivery

Package Size
50.00cm * 60.00cm * 60.00cm
Package Gross Weight
50.000kg

Product Description

VLF Advantage
1.AC Withstand voltage testing, Voltage & current curve display.
2.Tan delta (tgδ test for option), capacitance (μF) and IR (Ω) Test without external device (for buyer's option)
3.Partial discharge testing without external device (for buyer's option) .
4.DC withstandi voltage test,DC leakage current measurement (for option).
5."IEE 400.2" Analysis of Tan delta test result(for buyer's option) .
6.Safe Optical isolation technology.
7. Easiest to use Fully automatic microcontroller.
8. H/L voltage closed loop negative feedback control circuit, output no capacity rise effect.
9. Built-in printer.
10. Built-in protective resistors.                               
11. Colour Touch LCD (154*86mm)operation, True sine wave output.
12. Real-time display of actual output waveform.        
13. Ergonomic, menu guided, large colour touch screen
14. Storage of test results for later retrieval and print.                        
15. Over voltage and current protected.
16.Auto variable frequency 0.1Hz, 0.05Hz, 0.02 Hz, 0.01 Hz.
17. 60 mins continuous working;
18. Data of current, voltage and waveform directly sampled at HV side.
19. Rugged and reliable design less prone to failure from transients.
20. Invatation Patent                                                    
21. Portable: Control unit + Booster (Tank)
22. CE mark.
23. RS232 for option.
24. Remote control system for option


Vlf Hv Hipot High Voltage Tester with Tan Delta Tangent Diagnostics

Specification
1.Power: 220V ± 10% AC (110V can be customized), 50/60Hz, single phase;
2.Output-Voltage (Peak): 1 to rated value (KV), details see the below table;
3.Output frequency: 0.1Hz, 0.05Hz, 0.02 Hz, 0.01 Hz (auto variable frequency);
4.Load: 0.5μF (approx 6,000 ft of cable)  @ 0.1 Hz 
        1.0μF (approx 12,000 ft of cable) @ 0.05 Hz 
        2.5μF (approx 30,000 ft of cable) @ 0.02 Hz 
        5.0μF (approx 60,000 ft of cable) @ 0.01 Hz 
5. Stability of frequency: Fluctuation < 0.5%;
6. Measurement accuracy: ±3%;
7. Positive and negative voltage peak error: ≤3%;                              
8. Voltage waveform distortion: ≤5%;                                  
9. Construction: 1 Control unit + 1 Booster (60KV set);  1 Control unit + 2 Boosters(60KV set).
10. Ambient conditions of use: temperature Indoor and outdoor : -10ºC ~ + 50ºC.          
11. Humidity:≤85%  
12. Technical indexes of VLF tgδ test (for option):
  1) tgδ test voltage range: 1 to rated voltage (KV)
  2) Measurement voltage accuracy: 3%
  3) Dielectric loss test frequency: 0.1Hz
  4) Measurement range: 0.01×10-3- 655.35×10-3
  5) Dielectric loss accuracy: 1x10-4
  6) Dielectric loss resolution: 1x10-5
  7) Capacitance measurement range: 0.001μF-10μF
  8) Celectric capacity resolution: 0.001μF                     
  9) Current measurement range: 0-59mA                          
  10) Current resolution: 0.1mA
  11) Insulation resistance: 0.01GΩ-65.53GΩ
  12) Insulation resistance resolution: 10

13.Main technical indexes of VLF PD test (for buyer's option):
  1) Partial discharge measurement range: 0.1pc-5000pc
  2) Partial discharge detection sensitivity: 0.1pc
  3) Capacitance range: 0.001μF-10μF
  4) Sampling bits: 12 bits
  5) Sampling speed: 200M/S                                            
  6) Test voltage:  0 to rated value (KV)

14.DC leakage current measurement:
  1) Output rated voltage: same as rated AC voltage output
  2) Voltage accuracy: 3%
  3) Leakage current range: 0-2000μA or 0-20mA
  4) DC Current resolution: 1μA
  5) DC current accuracy: 3%
  6) It is necessary to parallel the capacitor we supplied if testing DC leakage current.
 

Model no
Output
Voltage/
Current
(Peak)
Load Capacity Control Unit Booster(Tank) Power 
Capacitance/
Freuency
Net Dim.
(cm)
Net Wt
 (kg)
Net Dim.
(cm)
Net Wt
(kg)
VLF-40TD  40KV/30mA 0.1Hz-0.01Hz
Auto Variable
Capacity:≤10µF
46×31×50   35   --   -- 1000W
VLF-80TD  80KV/59mA 0.1Hz-0.01Hz
Auto Variable
Capacity:5µF at 80KV
46×31×50   35 36x19×45     45 3000W
       
Vlf Hv Hipot High Voltage Tester with Tan Delta Tangent Diagnostics 


Vlf Hv Hipot High Voltage Tester with Tan Delta Tangent Diagnostics
Vlf Hv Hipot High Voltage Tester with Tan Delta Tangent Diagnostics
Vlf Hv Hipot High Voltage Tester with Tan Delta Tangent Diagnostics
Vlf Hv Hipot High Voltage Tester with Tan Delta Tangent Diagnostics
Vlf Hv Hipot High Voltage Tester with Tan Delta Tangent Diagnostics

Analysis of Tan delta test results (IEE400.2)
Vlf Hv Hipot High Voltage Tester with Tan Delta Tangent Diagnostics


Vlf Hv Hipot High Voltage Tester with Tan Delta Tangent Diagnostics

Field connection diagram
 Vlf Hv Hipot High Voltage Tester with Tan Delta Tangent Diagnostics         It gives 80KV output when external connecting 40KV tank.
              
Package for transport

1) 40KV test set:
Sr no  Name of Commodity  Qty  N.W  G.W Transport size
(LxWxH)
1 40KV test set
Including 1 capacitor
1 unit 35 kg 50 kg 580x400x500mm
                     Total: 1 set 35 kg 50 kg 0.12 m3
                                                        Packed in 1 wooden case.
 
 2) 80KV test set:
Sr no  Name of Commodity  Qty  N.W  G.W Transport size
(LxWxH)
1 Controll part 1 unit 35 kg 50 kg 550x400x500mm
2 Tank 1 unit 45 kg 69 kg 470x430x720mm
Capacitor 1 unit 4 kg
Aluminum alloy box   1 unit 6 kg
 
                     Total: 1 set 90 kg 119 kg 0.26 m3
                                                       Packed in 2 wooden cases.

Vlf Hv Hipot High Voltage Tester with Tan Delta Tangent Diagnostics
Accessories
Sr no.      Description Quantity Remarks
  1 Control part 1 unit  
  2 Booster  (Tank) 1 unit No tank for 40KV
  3 Capacitor (0.04µF) 1 unit Used as Capacity supplement, or test object for demo
  4 Discharge rod 1 unit  
  5 HV Test/Connection cables 1 set  
  6 Earth cable 1 unit  
  7 Power supply cable 1 unit  
  8 Fuse 2 units  
  9 Printer paper 1 unit  
 10 Operating manual 1 unit  
 11 Aluminium alloy box 1 unit No this item for 40KV
 12 Calibration report 1 unit  

Vlf Hv Hipot High Voltage Tester with Tan Delta Tangent Diagnostics
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier