0.1Hz Vlf Hipot Tester Integrated Tan Delta & Pd Test

Product Details
Customization: Available
After-sales Service: Life Time Maintenance
Warranty: One Year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • 0.1Hz Vlf Hipot Tester Integrated Tan Delta & Pd Test
  • 0.1Hz Vlf Hipot Tester Integrated Tan Delta & Pd Test
  • 0.1Hz Vlf Hipot Tester Integrated Tan Delta & Pd Test
  • 0.1Hz Vlf Hipot Tester Integrated Tan Delta & Pd Test
  • 0.1Hz Vlf Hipot Tester Integrated Tan Delta & Pd Test
  • 0.1Hz Vlf Hipot Tester Integrated Tan Delta & Pd Test
Find Similar Products

Basic Info.

Model NO.
VLF-60TD
Output Frequency
0.1Hz-0.01Hz
Colour
Black or Yellow
Transport Package
Plywood Case
Specification
CE
Trademark
GOLDSOL
Origin
China
HS Code
903033900
Production Capacity
50units/Month

Packaging & Delivery

Package Size
40.00cm * 50.00cm * 60.00cm
Package Gross Weight
50.000kg

Product Description

VLF (Very Low Frequency) Hipot Testers are suitable for testing power cables, transformers, switchgear, rotating machinery and other electrical apparatus.

For buyer's option:
1.Tan dleta (tgδ) test + Capacity(μF) + IR(Ω)
2."IEE 400.2" Analysis of Tan delta test result
3.Partial discharge PD(pc) testing
4.DC withstand voltage test (leakage current display)


-Micro-controller
-Advanced digital frequency technology
-Built-in printer
-Discharge free
-Portable
-60mins Continous working
-CE mark
-Patent
-5th generation

0.1Hz Vlf Hipot Tester Integrated Tan Delta & Pd Test

VLF Advantage
1.AC Withstand voltage testing, Voltage & current curve display.
2.Tan delta (tgδ test for option), capacitance (μF) and IR (Ω) Test without external device (for buyer's option)
3.Partial discharge testing without external device (for buyer's option) .
4.DC withstandi voltage test,DC leakage current measurement (for option).
5."IEE 400.2" Analysis of Tan delta test result(for buyer's option) .
6.Safe Optical isolation technology.
7. Easiest to use Fully automatic microcontroller.
8. H/L voltage closed loop negative feedback control circuit, output no capacity rise effect.
9. Built-in printer.
10. Built-in protective resistors.                               
11. Colour Touch LCD (154*86mm)operation, True sine wave output.
12. Real-time display of actual output waveform.        
13. Ergonomic, menu guided, large colour touch screen
14. Storage of test results for later retrieval and print.                        
15. Over voltage and current protected.
16.Auto variable frequency 0.1Hz, 0.05Hz, 0.02 Hz, 0.01 Hz.
17. 60 mins continuous working;
18. Data of current, voltage and waveform directly sampled at HV side.
19. Rugged and reliable design less prone to failure from transients.
20. Invatation Patent                                                    
21. Portable: Control unit + Booster (Tank)
22. CE mark.
23. RS232 for option.
24. Remote control system for option


Specification
1.Power: 220V ± 10% AC (110V can be customized), 50/60Hz, single phase;
2.Output-Voltage (Peak): 1 to rated value (KV), details see the below table;
3.Output frequency: 0.1Hz, 0.05Hz, 0.02 Hz, 0.01 Hz (auto variable frequency);
4.Load: 0.5μF (approx 6,000 ft of cable)  @ 0.1 Hz 
        1.0μF (approx 12,000 ft of cable) @ 0.05 Hz 
        2.5μF (approx 30,000 ft of cable) @ 0.02 Hz 
        5.0μF (approx 60,000 ft of cable) @ 0.01 Hz 
5. Stability of frequency: Fluctuation < 0.5%;
6. Measurement accuracy: ±3%;
7. Positive and negative voltage peak error: ≤3%;                              
8. Voltage waveform distortion: ≤5%;                                  
9. Construction: 1 Control unit + 1 Booster (60KV set);  1 Control unit + 2 Boosters(60KV set).
10. Ambient conditions of use: temperature Indoor and outdoor : -10ºC ~ + 50ºC.          
11. Humidity:≤85%  
12. Technical indexes of VLF tgδ test (for option):
  1) tgδ test voltage range: 1 to rated voltage (KV)
  2) Measurement voltage accuracy: 3%
  3) Dielectric loss test frequency: 0.1Hz
  4) Measurement range: 0.01×10-3- 655.35×10-3
  5) Dielectric loss accuracy: 1x10-4
  6) Dielectric loss resolution: 1x10-5
  7) Capacitance measurement range: 0.001μF-10μF
  8) Celectric capacity resolution: 0.001μF                     
  9) Current measurement range: 0-59mA                          
  10) Current resolution: 0.1mA
  11) Insulation resistance: 0.01GΩ-65.53GΩ
  12) Insulation resistance resolution: 10

13.Main technical indexes of VLF PD test (for buyer's option):
  1) Partial discharge measurement range: 0.1pc-5000pc
  2) Partial discharge detection sensitivity: 0.1pc
  3) Capacitance range: 0.001μF-10μF
  4) Sampling bits: 12 bits
  5) Sampling speed: 200M/S                                            
  6) Test voltage:  0 to rated value (KV)

14.DC leakage current measurement:
  1) Output rated voltage: same as rated AC voltage output
  2) Voltage accuracy: 3%
  3) Leakage current range: 0-2000μA or 0-20mA
  4) DC Current resolution: 1μA
  5) DC current accuracy: 3%
  6) It is necessary to parallel the capacitor we supplied if testing DC leakage current.

      

Model no
Output
Voltage
(AC/DC)

Output current
Load Capacity Fuse

Structure
Capacitance/
Frequency
 
VLF-30TD 1~30KV
AC: 20mA
DC: 2000μA
Auto/manual Frequency:0.1Hz-0.01Hz
Capacity≤10µF
(1.0µF@0.1Hz/30KV)
10A Integrated device:35kg
1 Capacior: 3kg
VLF-40TD 1~40KV
AC: 20mA
DC: 2000μA
Auto/manual
Frequency:0.1Hz-0.01Hz
Capacity≤10µF
(1.0µF@0.1Hz/40KV)
15A Integrated device:35kg
1 Capacior: 3kg
VLF-50TD 1~50KV
AC: 30mA
DC: 2000μA
Auto/manual Frequency:0.1Hz-0.01Hz
Capacity≤10µF
(1.0µF@0.1Hz/50KV)
20A Integrated device:40kg
1 Capacior: 4.2kg
VLF-60TD 1~60KV
AC: 59mA
DC: 2000μA
Auto/manual Frequency:0.1Hz-0.01Hz
Capacity≤5µF
(0.5µF@0.1Hz/60KV)
20A Integrated device:40kg
1 Capacior: 4.2kg
VLF-70TD 1~70KV
AC: 59mA
DC: 2000μA
Auto/manual Frequency:0.1Hz-0.01Hz
Capacity≤5µF at 70KV;
≤10µF at 50KV
(0.5µF@0.1Hz/70KV)
30A Control part:35kg
(Controller+1*30KV tank)
1*40KV tank: 45kg
1 Capacior: 4.2kg
VLF-80TD 1~80KV
AC: 59mA
DC: 2000μA
Auto/manual Frequency:0.1Hz-0.01Hz
Capacity≤4µF at 80KV
≤10µF at 50KV
(0.4µF@0.1Hz/80KV)
30A Control part:35kg
(Controller+1*40KV tank)
1*40KV tank: 45kg
1 Capacior: 4.2kg
Note: DC leakage current measurement for buyer's option.
 
0.1Hz Vlf Hipot Tester Integrated Tan Delta &amp; Pd Test 



0.1Hz Vlf Hipot Tester Integrated Tan Delta &amp; Pd Test
0.1Hz Vlf Hipot Tester Integrated Tan Delta &amp; Pd Test
0.1Hz Vlf Hipot Tester Integrated Tan Delta &amp; Pd Test
0.1Hz Vlf Hipot Tester Integrated Tan Delta &amp; Pd Test
0.1Hz Vlf Hipot Tester Integrated Tan Delta &amp; Pd Test

Analysis of Tan delta test results (IEE400.2)
0.1Hz Vlf Hipot Tester Integrated Tan Delta &amp; Pd Test

0.1Hz Vlf Hipot Tester Integrated Tan Delta &amp; Pd Test

Field connection diagram
 0.1Hz Vlf Hipot Tester Integrated Tan Delta &amp; Pd Test     It gives 80KV output when external connecting 40KV tank.
              
Package for transport

1) 60KV test set:
Sr no  Name of Commodity  Qty  N.W  G.W Transport size
(LxWxH)
1 60KV test set
Including 1 capacitor and 1 wires case
1 unit 46 kg 80 kg 580x400x500mm
                     Total: 1 set 46 kg 80 kg 0.19 m3
                                                        Packed in 1 wooden case.
 
 2) 80KV test set:
Sr no  Name of Commodity  Qty  N.W  G.W Transport size
(LxWxH)
1 Controll part 1 unit 45 kg 50 kg 550x400x500mm
2 Tank 1 unit 45 kg 69 kg 470x430x720mm
Capacitor 1 unit 4 kg
Aluminum alloy box   1 unit 6 kg
 
                     Total: 1 set 90 kg 119 kg 0.26 m3
                                                       Packed in 2 wooden cases.

0.1Hz Vlf Hipot Tester Integrated Tan Delta &amp; Pd Test
Accessories
Sr no.      Description Quantity Remarks
  1 Control part 1 unit  
  2 Booster  (Tank) 1 unit No external tank for 30KV,40KV,50KV, 60KV
  3 Capacitor (0.04µF) 1 unit Used as Capacity supplement, or test object for demo
  4 Discharge rod 1 unit  
  5 HV Test/Connection cables 1 set  
  6 Earth cable 1 unit  
  7 Power supply cable 1 unit  
  8 Fuse 2 units  
  9 Printer paper 1 unit  
 10 Operating manual 1 unit  
 11 Aluminium alloy box 1 unit  
 12 Calibration report 1 unit  


0.1Hz Vlf Hipot Tester Integrated Tan Delta &amp; Pd Test