I. Product introduction
We designed & produced Model no.HMJS-3 insulating boots ( gloves ) dielectric test equipment based on charged protective equipment insulation test procedures, and compliance with the majority of users opinions. The product has an effective solution for the past irregular testing method, thereby simplifying the testing procedures, improving the test speed. A more reliable identification of insulating boots ( gloves ) leakage current, insulation aging, power frequency withstand voltage and other parameters. To protect operator safety, so it is the ideal insulation boots ( gloves ) and special equipment.
It can be tested simultaneously 3 pair of insulating boots ( gloves ), and it can read leakage current of each glove to judge unqualified insulating boots ( gloves ); structure bottom assembly casters, it can freely move.
II. Working principle
0~220V power supply, regulating power frequency voltage withstand test according to the principle of electromagnetic induction of test transformer, to make transformer output 0~50KV high voltage to each electrode, so that insulating boots ( gloves ) obtain the test voltage specified. According to the insulating boots ( gloves ) test procedures, read, record test parameters.
Kits use wiring diagram shown as below( Micrometer 6 pics )
1.Boots & Gloves Testing Trolley
2.Boots & Gloves testing connection
III. Structure design
1.Control unit
1) Input voltage: AC220V±10% 50/60Hz
2) Output voltage: AC 0~30KV, or 0~50KV as per buyer's option
3) LV currency: 0~25A
4) Output capacitance: 0~5kVA
5) Timig range: 0~999S
6) Voltage accuracy: ≤2% (F.S)
7) Currency accuracy: ≤1.5% (F.S)
8) Leakage current: 0~50mA
9) Leakage current resolution: 0.1mA
10 Ambient temperature: -20ºC~50ºC
11) Test number : 3 pairs each
12) GW/NW: 40kg/30kg
2.Transformer
1) Capacity:5KVA
2) Input Voltage:AC200V 50Hz
3) Power Input:25A
4) Output Voltage:AC 0-50KV (AC 0~30KV for Boots & Gloves testing)
5) Power Output:AC 0-100mA
6) Size: 360×255×650mm
7) GW/NW: 65kg/50kg
3.Trolley equimpent, including trollery, moving bracket, sinks, electrode rod support...
(Trolley with protective tools: NW42kg; GW70kg).
1) Moving bracket;
2) Sink;
3) Insulating rod
4) Electrode rod support;
5) High voltage terminal;
6) Leakage measurement terminal
IV. Transport weight and demension:
Name of Commodity |
Qty |
G.W(KG) |
N.W(KG) |
Measurement(CM) |
Control unit |
1 unit |
40 kgs |
30 kgs |
57*40*50 cm |
Booster |
1 unit |
65 kgs |
50 kgs |
45*40*85 cm |
Inslation Test Trolley |
1 unit |
69 kgs |
42 kgs |
84*107*107cm |
|
3 units |
174 kgs |
122 kgs |
1.23 m3 |
Packed in 3 wooden cases (All Picture just for reference). |
V. Accessories
Sr no |
Description |
Qty |
1 |
Power supply cable |
1 unit |
2 |
Test cables |
1 set |
3 |
Factory's test report |
1 unit |
4 |
Operating manual |
1 unit |