Power Frequency Partial Discharge Hipot Testers Test Equipments

GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
  • Audited Supplier
  • 15 yrs

Contact Supplier

Product Highlights

  • Lifetime Maintenance: Provides life time maintenance service for the equipment.
  • 1-Year Warranty: Covers mechanical defects with a one-year warranty period.
  • 50kV Test Voltage: Designed for power products under 50KV test voltage.
  • 10.1 Inch Touch Screen: Features a full touch screen for convenient operation and data upload.
  • High Sensitivity Detection: Capable of detecting partial discharge from 0.1pc to 10000nc.
  • SF6 Dielectric Medium: Uses SF6 gas as the dielectric medium for the test transformer.
  • Wide Frequency Bands: Supports nine kinds of multiple frequency band combinations.
  • Fast Lead Time: Average lead time within 15 workdays for both peak and off seasons.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Power Frequency Partial Discharge Hipot Testers Test Equipments

Power Frequency Partial Discharge Hipot Testers Test Equipments pictures & photos
Power Frequency Partial Discharge Hipot Testers Test Equipments
Power Frequency Partial Discharge Hipot Testers Test Equipments pictures & photos
Power Frequency Partial Discharge Hipot Testers Test Equipments
Power Frequency Partial Discharge Hipot Testers Test Equipments pictures & photos
Power Frequency Partial Discharge Hipot Testers Test Equipments
Power Frequency Partial Discharge Hipot Testers Test Equipments pictures & photos
Power Frequency Partial Discharge Hipot Testers Test Equipments
Power Frequency Partial Discharge Hipot Testers Test Equipments pictures & photos
Power Frequency Partial Discharge Hipot Testers Test Equipments
Power Frequency Partial Discharge Hipot Testers Test Equipments pictures & photos
Power Frequency Partial Discharge Hipot Testers Test Equipments
  • Power Frequency Partial Discharge Hipot Testers Test Equipments
    Power Frequency Partial Discharge Hipot Testers Test Equipments
  • Power Frequency Partial Discharge Hipot Testers Test Equipments
    Power Frequency Partial Discharge Hipot Testers Test Equipments
  • Power Frequency Partial Discharge Hipot Testers Test Equipments
    Power Frequency Partial Discharge Hipot Testers Test Equipments
  • Power Frequency Partial Discharge Hipot Testers Test Equipments
    Power Frequency Partial Discharge Hipot Testers Test Equipments
  • Power Frequency Partial Discharge Hipot Testers Test Equipments
    Power Frequency Partial Discharge Hipot Testers Test Equipments
  • Power Frequency Partial Discharge Hipot Testers Test Equipments
    Power Frequency Partial Discharge Hipot Testers Test Equipments

Find Similar Products

Product Description

I. Application:
This equipment is mainly used under ≤ 50KV test voltage for power products such as transformers, power transformers, high voltage circuit breakers, cables accessories, products for power frequency voltage withstand test and partial discharge test and research pilot.

II. Working Conditions:
Altitude: ≤ 2500m
Temperature: -15ºC ~ +45ºC
Relative humidity: ≤90%RH

III. Standard
JB/T9641-1999  .........…Test Transformer
GB/T.311.1-1997  ......…Insulated high-voltage transmission and distribution equipment and cooperation
GB/T 16927.1-1997  ......…HV Test TechnologyCharter 1
GB/T 16927.2-1997.........HV Test TechnologyCharter 2
GB7328-87............…Transformer and reactor sound levels measured
GB/7354-2003 .........…PD Test
GB/T509-1991 .........…Power Transformer Test Rule
GB2536-1990............Transformer Oil
GB7252-87............…Transformer oil dissolved gas analysis and assessment guidelines
JB8749-1998............General requirements for voltage regulator

IV. Equipment components
 
Sr no Name of Commodity
 
 Model number  Qty
 (unit)
 1 PD Test Transformer YDQW-5KVA/50KV      1
 2 PD Test Control unit 5kVA/200V      1
 3 Power Isolation Filter 5kVA/220V 1
 4 PD Coupling Capacitor 50kV/200pF 1
 5 Current Limit Resistor 50kV/5K 1
 6 PD Analyzer HSJFD-3A   1
 7 Calibrator JZF-9 or JZF-10   1
 8 Input unit 3#   1
            
Power Frequency Partial Discharge Hipot Testers Test Equipments

PD Test Transformer  10KVA /50KV/200V
1. Rated capacity: 5kVA
2. Output voltage:0- 50kV
3. Input voltage: 200V ±10%
4. PD Volume under rated voltage ≤ 5PC
5..Output Current: 100mA
6. Phase: Single Phase
7. Voltage accuracy: AC 1.5%
8.Power supply distortion: <3%   
9. Dielectric medium: SF6
10.Size: Ф320*800mm
11. Weight: 45kgs

Control unit,  5KVA/200V
Functon:
1.Zero position function,digital voltage/current display.
2.Time Ralay control alarming warning; alarm with light
3.Over-current/voltage protection, breakdown protection.
4.Continuous adjusting voltage, without waveform distortion.
5. Voltage return to zero when testing is over.

Parameters:
1.Rated capacitance: 5kva
2.Input voltage:220V±10%
3.Output current: 22.7A
4.Output voltage: 0-250V
5.Size: 400*350*350mm
6.Weight:24kgs

Power Isolation Filter,  5kVA/220V
1.Input Voltage:220V±10%
2.Output voltage:220V±10%
3. Rated Capacitance:5KVA
4. Resistance voltage: ≤5%
5.Unload loss: ≤5%
5. Reduction Character:10KHz~100KHz ≥20dB; 100KHz~30MKHz ≥60dB
6. PD level:Q≤ 5PC under rated voltage
7. Size:350 × 350 × 420mm
8. Weight:30Kg

PD Coupling Capacitor  50kV/200pF
1.Capacitance: 200pF
2.PD Volume:≤ 5PC
3.Coupling Capacity: 50KV
4.Equipotential shielding: 1 unit
4.Size: Height 800mm, Ф80mm
5.Weight: 23kgs

Current Limit Resistor, 50kV/5K
1.Creepage:>50KV
2.Height: 300mm, Ф60mm
3.Weight: 2.5kgs

PD Analyzer,  HSJFD-3A
HSJFD-3A partial discharge detector is a new type of digital partial discharge detector developed by our company. It retains the advantages of HSJFD-3A partial discharge detector, reduces the volume and optimizes the performance. It uses 10.1 inch touch screen to replace the traditional operation mode of oscillograph and physical knob, making it more convenient to use.
The instrument adopts full touch screen operation, which not only improves the service life of the operation, but also has the following functions: one key automatic correction; high voltage test voltage divider ratio can be set; serial communication upload test data. The instrument has the characteristics of high sensitivity, wide application range, wide dynamic range of amplification system, multiple frequency band combinations (nine kinds), and strong anti-interference ability. It is a practical partial discharge testing instrument widely used by electric power departments, manufacturers and scientific research institutes.

Power Frequency Partial Discharge Hipot Testers Test Equipments
Main Technical Indicators for PD tester:
1. The equivalent capacitance ranges from 6pF to 250 μ F
2. Number of channels: single channel
3. Measurement range: 0.1pc-10000nc
4. Detection sensitivity and allowable current (see Table 1)
NO. Tuning Capacitance Range Sensitivity (PC)
(Unbalanced Circuit)
Effective Value Of Allowable Current
Unbalanced Circuit Balance Circuit
1 0~25~100pF 0.02 30mA 0.25A
2 25~100~400pF 0.04 50mA 0.5A
3 100~400~1500pF 0.06 120mA 1A
4 400~1500~6000pF 0.1 0.25A 2A
5 1500~6000~25000pF 0.2 0.5A 4A
6 0.006~0.025~0.1μF 0.3 1A 8A
7 0.025~0.1~0.4μF 0.5 2A 15A
8 0.1~0.4~1.5μF 1 4A 30A
9 0.4~1.5~6.0μF 1.5 8A 60A
10 1.5~6.0~25μF 2.5 15A 120A
11 6.0~25~60μF 5 25A 200A
12 25~60~250μF 10 50A 300A
7R Resistance 0.5 2A 15A
Table:Detection sensitivity and allowable current value of input unit

5. Elliptic scan time base
(1) Frequency 50/60, 100, 150, 200, 400Hz
(2) Rotation: 30 ° as the first gear, and can rotate 120 °
(3) Working method: ellipse sine wave straight line

6. Display unit
10.1 inch capacitive touch screen is used.

7. Amplifier
(1) 3dB low frequency fl:10, 20, 40KHz optional
(2) 3dB high frequency fh:80, 200, 300kHz optional
(3) Gain adjustment, rough adjustment 6, inter gear gain difference 20 ± 1dB,
fine adjustment range >20db
(4) Asymmetry of positive and negative pulse response < 1dB

8. Time window
(1) Window width: adjustable, 5 ° ~ 170 ° at 50Hz
(2) Window position: each window can rotate 0 ° ~ 170 °
(3) Two time windows can be opened separately or simultaneously.

9. Peak pulse display
The touch screen displays 1 decimal place (10pc or more), 2 decimal places (less than 10pc),
error: ± 3% (in full scale)

10. Test voltage display
(1) Range 150kV
(2) Input impedance: >1m Ω
(3) Display: touch screen display, display 1 decimal place
(4) Error: ± 1% 

11. Test frequency display
Error: less than ± 1%

12. Zero standard system
Zero sign is consistent with all ellipse scanning frequencies

13. Structure
(1) Dimensions: 370mm (width), 460mm (depth), 215mm (height)
(2) Weight: about 12.5kg

Calibrator
1. Output charge position: 5 PC, 50PC, 500PC
2. Polarity: positive and negative alternation
3. Repetition frequency: 1.2KHz
4. Frequency range:  >±100Hz
5. Pulse rise time: <100ns
6. Pulse fall time: >100us
7. Injection capacitance: 10PF, 100PF
8. Capacitance error: Ec ≤ ±4%
9. Square wave voltage amplitude error: Eu ≤ ±4% (50PC position)
10. Correction charge error: Eq=(Eu2+Ec2)1/2  ≤±5%
11. Battery: 6F22 9V
12.Size: 160 x 125 x 50mm3
13.Weight: 0.5kg


V. Connection sketch
  
Power Frequency Partial Discharge Hipot Testers Test Equipments



VI. Transport size and weight
Sr no Desscription Qty  NW
 (KG)
 GW
 (KG)
  Dimension
    (CM)
Unit Package

  1
YDQW-5KVA/50KV
PD CONTROL UNIT

1

1

@24 kgs
 
@36 kgs

@47*37*38cm
 
2
YDQW-5KVA/50KV
PD TEST TRAMSFORMER

1

1

@45kgs
 
@65 kgs

@40*45*97cm
 
3
YDQW-5KVA
POWER ISOLATION FILTER

1

  1

@30kgs
 
@55 kgs

@45*45*55cm

4
YDQW-50KV/200pF
PD COUPLING CAPACITOR

1

1

@25kgs
 
@43 kgs

@98*38*42cm

5
HSJFD-3A
PARTIAL DISCHARGE TESTER

1

1

@22kgs
 
@38 kgs

@60*62*40cm
                          
        Total                 

5 Wooden cases

146 kgs

237 kgs
  
    0.66 m3
Note: Real for the final.


 

About the Supplier

Watch Video
Watch Video
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY

About Our Factory & Business Background

Address
Room 507, Unit 1, Building 1, Optical Valley, Tanhu 1st Road, Canglong Island, Jiangxia District, Wuhan China
Terms of Payment
LC, T/T, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, CFR, CIF, DAT, FAS, DDP, DAP, CPT, FCA, EXW
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Wuhan/Shanghai/Shenzhen/Guangzhou

Our Production Capability & Technical Expertise

Main Products
Vlf Hipot Testers, AC Hipot Tester, DC Hipot Tester, Resonant Test Set, Micro Ohmmeter, Tan Delta Tester, Primary Current Injection, Secondary Current Injection, CT PT Analyzer, Circuit Breaker Analyzer

Our Industry Experience & Global Business Record

Export Year
2006-05-10
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the warranty period for this equipment?
We provide a comprehensive one-year warranty for all mechanical defects.
Does the equipment come with after-sales support?
Yes, we offer life time maintenance service for the equipment.
What is the maximum test voltage this tester supports?
This equipment is mainly used for power products under 50KV test voltage.
How long does it take to deliver the product?
The average lead time is within 15 workdays for both peak and off seasons.
What is the detection sensitivity range?
The measurement range is from 0.1pc to 10000nc with high sensitivity.
What type of display does the PD Analyzer use?
It uses a 10.1 inch capacitive touch screen for full touch screen operation.
What is the dielectric medium used in the transformer?
The dielectric medium used is SF6 gas.
Can the test frequency be adjusted?
Yes, the elliptic scan time base supports frequencies of 50/60, 100, 150, 200, and 400Hz.