Current Interruption Test Set 3000A

Product Details
Customization: Available
Max Diameter of Workpiece: L
Mass Scope of Workpiece: Light
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Current Interruption Test Set 3000A
  • Current Interruption Test Set 3000A
  • Current Interruption Test Set 3000A
  • Current Interruption Test Set 3000A
  • Current Interruption Test Set 3000A
  • Current Interruption Test Set 3000A
Find Similar Products

Basic Info.

Model NO.
DDG-3000A
Maxcapacity
L
Load Way
Mechanical Load
Loading Method
Dynamic Load
Display
Digital
Control
Manual Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
L
Primary Current Injection
Primary Current Injection 2000A
Transport Package
Plywood Case Outside
Specification
CE
Trademark
GOLDSOL
Origin
China
HS Code
903033200
Production Capacity
20sets/Month

Packaging & Delivery

Package Size
45.00cm * 45.00cm * 70.00cm
Package Gross Weight
140.000kg

Product Description

I. Introduction
Strong current generator is the necessary equipment in places of strong current. It is widely used in power plants, power distribution stations, electrical manufacturers, research institutes and other departments. The equipment has the characters of short-term or intermittent system, small size, light weight and easy maintenance and so on.

II. Structure
The product has full metal shell and aluminum-alloy panel combination with  reasonable structure, elegant appearance, light weight and easy move.

Current Interruption Test Set 3000A
1: Start  Button      2: Stop Button    3: Current Regulation Handle
4: Current Switch  5: Strong Current Indicator 6: Power Indicator
7: Weak Current Indicator 8: Voltage Switch 9: Operation Indicator
10: Voltage indicator   11: Strong Current Output   12 & 13:Power Input


III. Instructions

1.Connect the current amplifier with the tested product according to the testing requirements, and make sure that there's power supply. (For split type, connect the "input" on the panel with the power, the "output" with the "input" on DDK, and the "instrument" with the "instrument" on DDK.

2.
Select the position of Current Switch according to the needed current.

3.
Turn on the power, and the green light should be on (if not, turn the Voltage Switch counterclockwise to zero until the green light is on). Press the Startup Button, the green light should be off and the red light is on. Turn the Voltage Switch clockwise until the current rises to the needed level.

4.Turn the Voltage Switch counterclockwise to zero, press the Stop Button, the red light is off and the green light is on. The testing is over.

Current Interruption Test Set 3000A


IV. Electrical Diagram
1. Diagram of Current Generator
     Current Interruption Test Set 3000A
2.Output copper wires connection method at open-backed door: 
Current Interruption Test Set 3000A
V. Maintenance Notes
1. when acceptance of goods, please check the main circuit terminal block if it is loose, or if elecrical brush of regulator is with a  good contact.

2. when not using for a long time, please check the main circuit of insulation earth resistance with 500V Megohmmeter before the equipment will be used, the resistance should be not less than 0.5 MΩ.

3. Input voltage value should be ± 10%, frequency 50HZ.

4. Current switch are not allowed to operate with load.

5. Operation should be equably & slowly rotating hand wheel to avoid damaging the regulator.

6. Full load hours should not exceed 5 minutes, continuous work time should be less than 2.5 minutes, but the working cycle should be more than 10 minutes.

7. Earth terminal should be well grounded.


VI. Technical Parameters and Specifications for DDG series (Single phase)
 

Model
Capacity of Current Amplifier
(KVA)
Capacity of Voltage Regulator
(KVA)
Supply Voltage
(V)
No.of Phase
Remark
DDG-500A 3 2 220 1   1 unit
DDG-1000A 6 5 220 1   1 unit
DDG-1500A 9 10 220 1   1 unit
DDG-2000A 12 10 220 /380 1 2 1unit/2unit 
DDG-2500A 15 10 380 1 2 1unit/2unit 
DDG-3000A 18 15 380   2 1unit/2unit 
DDG-4000A 24 20 380   2 2 unit
DDG-5000A 30 28 380   2 2 unit
DDG-6000A 36 30 380   2 2 unit
DDG-8000A 48 40 380   2 2 unit
DDG-10000A 60 50 380   2 2 unit
DDG-15000A 90 75 380   2 2 unit
DDG-20000A 120 100 380   2 2 unit


   VII. Accessories
 Sr no Description Qty Remarks
   1 Power supply cable 1  
   2 Connection cables 1  
   3 Earth cable 6m 1  
   4 Operating manual 1  
   5 Factory's calibration 1  
   6 Strong current cables 2 For buyer's option

Current Interruption Test Set 3000A

Current Interruption Test Set 3000A

Current Interruption Test Set 3000A






 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier