Secured Trading Service

Power Frequency Withstand Voltage Partial Discharge Test Set

GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
  • Audited Supplier
  • 15 yrs

Contact Supplier

Product Highlights

  • Lifetime Maintenance: Comprehensive after-sales service covering the entire product lifecycle.
  • One Year Warranty: Full warranty coverage for one year from the date of purchase.
  • 100KV Test Voltage: Designed for power frequency withstand voltage tests up to 100KV.
  • SF6 Dielectric Medium: Uses SF6 gas for superior insulation and dielectric strength.
  • High Accuracy Measurement: Voltage accuracy of AC 1.5% with low noise and high sensitivity.
  • Multi-Channel Interface: Four-channel test interface for convenient and simultaneous testing.
  • Wide Capacitance Range: Testing scope covers 6PF to 250uF with adjustable sensitivity.
  • Compliance with Standards: Meets JB/T9641-1999 and GB/T 16927.1-1997 technical standards.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Power Frequency Withstand Voltage Partial Discharge Test Set

Power Frequency Withstand Voltage Partial Discharge Test Set pictures & photos
Power Frequency Withstand Voltage Partial Discharge Test Set
Power Frequency Withstand Voltage Partial Discharge Test Set pictures & photos
Power Frequency Withstand Voltage Partial Discharge Test Set
Power Frequency Withstand Voltage Partial Discharge Test Set pictures & photos
Power Frequency Withstand Voltage Partial Discharge Test Set
Power Frequency Withstand Voltage Partial Discharge Test Set pictures & photos
Power Frequency Withstand Voltage Partial Discharge Test Set
Power Frequency Withstand Voltage Partial Discharge Test Set pictures & photos
Power Frequency Withstand Voltage Partial Discharge Test Set
Power Frequency Withstand Voltage Partial Discharge Test Set pictures & photos
Power Frequency Withstand Voltage Partial Discharge Test Set
  • Power Frequency Withstand Voltage Partial Discharge Test Set
    Power Frequency Withstand Voltage Partial Discharge Test Set
  • Power Frequency Withstand Voltage Partial Discharge Test Set
    Power Frequency Withstand Voltage Partial Discharge Test Set
  • Power Frequency Withstand Voltage Partial Discharge Test Set
    Power Frequency Withstand Voltage Partial Discharge Test Set
  • Power Frequency Withstand Voltage Partial Discharge Test Set
    Power Frequency Withstand Voltage Partial Discharge Test Set
  • Power Frequency Withstand Voltage Partial Discharge Test Set
    Power Frequency Withstand Voltage Partial Discharge Test Set
  • Power Frequency Withstand Voltage Partial Discharge Test Set
    Power Frequency Withstand Voltage Partial Discharge Test Set

Find Similar Products

Product Description

I. Application:
This equipment is mainly used under ≤ 100KV test voltage for power products such as transformers, power transformers, high voltage circuit breakers, cables accessories, products for power frequency voltage withstand test and partial discharge test and research pilot.


II. Working Conditions:
Altitude: ≤ 2500m
Temperature: -15ºC ~ +45ºC
Relative humidity: ≤90%RH


III. Standard
JB/T9641-1999  .........…Test Transformer
GB/T.311.1-1997  ......…Insulated high-voltage transmission and distribution equipment and cooperation
GB/T 16927.1-1997  ......…HV Test TechnologyCharter 1
GB/T 16927.2-1997.........HV Test Technology Charter 2
GB7328-87............…Transformer and reactor sound levels measured
GB/7354-2003 .........…PD Test
GB/T509-1991 .........…Power Transformer Test Rule
GB2536-1990............Transformer Oil
GB7252-87............…Transformer oil dissolved gas analysis and assessment guidelines
JB8749-1998............General requirements for voltage regulator


IV. Equipment components
1.PD Test Transformer (5KVA /100KV) ........................................................................ 1 unit
2.Test Controller (5KVA/200V) ....................................................................................1 unit
3.Power Isolation Filter (5KVA/200V)..........................................................................1 unit
4.PD Coupling Capacitor(100KV/200pF) ....................................................................1 unit
5.Current Limit Resistance(100kV/5K ohm)........................................................................1 unit
6.Partial Discharge Analyzer (HSJFD-3A)..................................................................1 unit
7.Partial Discharge Calibrator (JZF-9)...........................................................................1 unit
8.Type 3,4,5 Input Unit ..................................................................................................3 units

Power Frequency Withstand Voltage Partial Discharge Test Set
Power Frequency Withstand Voltage Partial Discharge Test Set
Power Frequency Withstand Voltage Partial Discharge Test Set

PD Test Transformer  5KVA /100KV/200V

1. Rated capacity: 5kVA
2. Output voltage:0- 50kV
3. Input voltage: 200V ±10%
4. PD Volume under rated voltage ≤ 5PC
5..Output Current: 100mA
6. Phase: Single Phase
7. Voltage accuracy: AC 1.5%
8.Power supply distortion: <3%   
9. Dielectric medium: SF6
10.Size: Ф320*800mm
11. Weight: 45kgs


Control unit,  5kVA/200V

Functon:
1.Zero position function,digital voltage/current display.
2.Time Ralay control alarming warning; alarm with light
3.Over-current/voltage protection, breakdown protection.
4.Continuous adjusting voltage, without waveform distortion.
5. Voltage return to zero when testing is over.

Parameters:
1.Rated capacitance: 5kva
2.Input voltage:220V±10%
3.Output current: 25A
4.Output voltage: 0-250V 
5.Size:
400*360*350mm
6.Weight:25kgs


Power Isolation Filter (5KVA),  5kVA/200V
 
1.Input Voltage:200V±10%
2.Output voltage:200V±10%
3. Rated Capacitance:5KVA
4. Resistance voltage: ≤5%
5.Unload loss: ≤5%
5. Reduction Character:10KHz~100KHz ≥20dB; 100KHz~30MKHz ≥60dB
6. PD level:Q≤ 5PC under rated voltage
7. Size:350 × 350 × 420mm
8. Weight:30Kg

PD Coupling Capacitor  100kV/200pF
 
1.Capacitance: 200pF
2.PD Volume:≤ 5PC
3.Coupling Capacity: 100KV
4.Equipotential shielding: 1 unit
4.Size: Height 800mm, Ф80mm
5.Weight: 23kgs


Current Limit Resistance, 100kV/2K
 
1.Creepage:>100KV
2.Height: 300mm, Ф60mm
3.Weight: 2.5kgs


PD Analyzer,  HSJFD-3A

Feature:
1. large scale integrated circuit make the tester more stable and accurate..
2. large-screen CRT, the screen area to work effectively 100 × 80mm, can be clearly observed discharge waveform.
3. Four-channel test interface, more convenient testing.
4. using double-header shows the amount of discharge, both figures table shows PC value, while another pointer header shows PC value, the pointer table can be divided into linear and logarithmic instructions.
5. Low noise, high detection sensitivity, wide capacitance coverage area
6. Small size and light weight make it easy to carry.

Main technical index:
1.Testing scope: 6PF - 250uF
2.Sensitivity: 0.02PC
Input unit Tuning capacity Unit Sensitivity (asymmetric circuit)
1 6-25-100 µµF 0.02
2 25-100-400 µµF 0.04
3 100-400-1500 µµF 0.06
4 400-1500-6000 µµF 0.1
5 1500-6000-25000 µµF 0.2
6 0.006-0.025-0.1 µF 0.3
7 0.025-0.1-0.4 µF 0.5
8 0.1-0.4-1.5 µF 1.0
9 0.4-1.5-6.0 µF 1.5
10 1.5-6.0-25 µF 2.5
11 6.0-25-60 µF 5.0
12 25-60-250 µF 10
7R Resistance µF  0.5

Power Frequency Withstand Voltage Partial Discharge Test Set
 
3.Amplifier band:
   (1) low-end: 10KHZ, 20KHZ, 40KHZ optional
   (2) high-end: 80KHZ, 200KHZ, 300KHZ optional
4.Amplifier adjustment:
6 coarse grade, 20db each grade;
scope of fine-tune> 20db.
5.Time window:
   (1) Window Width: 15 - 150°Adjustable  
   (2) Window Position: Each window can be rotated 0 -170°
   (3) 2 windows can be opened separately or simultaneously.
6.Discharge scale:
   (1) Analog Meter: logarithmic scale 1-10-100, error<5%
      linear scale 0-1000 Error<5% (based on full-scale meter)
   (2) Digital Header: 3.5 LED shows 0-100, error<5%
7.Elliptical:
   (1) Frequency 50HZ, 100HZ, 150HZ, 200HZ, 400HZ
   (2) Elliptical rotation: 30°each grade, it can be used for 120°rotation
   (3) Display: Oval - straight line
   (4) high-frequency input voltage:13V-275V,  power:<1VA 
8.Testing Voltmeter:
   (1) Range: 100KV (expandable)
   (2) Display: 3.5 digital voltmeter instructions
   (3) Accuracy: 5%
9. Power supply: 220V
10.Size:530×550×220mm3
11.Weight:22KG


Calibrator

1. Output charge position: 5 PC, 50PC, 500PC
2. Polarity: positive and negative alternation
3. Repetition frequency: 1.2KHz
4. Frequency range:  >±100Hz
5. Pulse rise time: <100ns
6. Pulse fall time: >100us
7. Injection capacitance: 10PF, 100PF
8. Capacitance error: Ec ≤ ±4%
9. Square wave voltage amplitude error: Eu ≤ ±4% (50PC position)
10. Correction charge error: Eq=(Eu2+Ec2)1/2  ≤±5%
11. Battery: 6F22 9V
12.Size: 160 x 125 x 50mm3
13.Weight: 0.5kg


V. Connection sketch

Power Frequency Withstand Voltage Partial Discharge Test Set

      









 

About the Supplier

Watch Video
Watch Video
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY

About Our Factory & Business Background

Address
Room 507, Unit 1, Building 1, Optical Valley, Tanhu 1st Road, Canglong Island, Jiangxia District, Wuhan China
Terms of Payment
LC, T/T, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, CFR, CIF, DAT, FAS, DDP, DAP, CPT, FCA, EXW
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Wuhan/Shanghai/Shenzhen/Guangzhou

Our Production Capability & Technical Expertise

Main Products
Vlf Hipot Testers, AC Hipot Tester, DC Hipot Tester, Resonant Test Set, Micro Ohmmeter, Tan Delta Tester, Primary Current Injection, Secondary Current Injection, CT PT Analyzer, Circuit Breaker Analyzer

Our Industry Experience & Global Business Record

Export Year
2006-05-10
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the warranty period for this equipment?
We provide a one-year warranty for all mechanical and electrical components.
What is the maximum test voltage supported?
The equipment is designed for power frequency withstand voltage tests up to 100KV.
Does the product come with after-sales support?
Yes, we offer lifetime maintenance service to ensure long-term operational reliability.
What is the dielectric medium used in the test transformer?
The PD Test Transformer utilizes SF6 gas as the dielectric medium for enhanced insulation.
What is the accuracy of the voltage measurement?
The voltage accuracy is maintained at AC 1.5% with power supply distortion below 3%.
What is the testing capacitance range?
The testing scope covers a wide range from 6PF to 250uF with adjustable sensitivity levels.
Which international standards does this set comply with?
It complies with JB/T9641-1999, GB/T 16927.1-1997, GB/T 16927.2-1997, and other relevant standards.
What is the lead time for delivery?
The average lead time is within 15 workdays for both peak and off-peak seasons.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now