Customization: | Available |
---|---|
After-sales Service: | Life Time Maintenance |
Warranty: | One Year |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make at Made-in-china.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Usage | Class P/TP CT & VT | |
Output | 0~180Vrms,12Arms,18A(peak value) | |
Voltage measurement accuracy | ±0.05% | |
CT Ratio | Range | 1~30000 |
accuracy | ±0.05% | |
PT Ratio | Range | 1~30000 |
accuracy | ±0.05% | |
Phase | Range | ±5min |
accuracy | 0.5min | |
DC resistance | Range | 0~300Ω |
accuracy | 2%±2mΩ | |
Burden | Range | 0~300VA |
accuracy | 2%±0.2VA | |
Power supply | AC220V±10%,50Hz | |
Environmental Conditions | Operating temperature :-10ºC~50ºC,Humidity :≤90% | |
Weight and Dimensions | Dimensions:340 mm×300 mm×150mm,Weight<9kg |
result | description | P | TPY | M | PR | PX | TPS | TPX | TPZ | |
Load | Actual load | unit:VA,CT secondary measure actual load | √ | √ | √ | √ | √ | √ | √ | √ |
Power factor | Power factor of actual load | √ | √ | √ | √ | √ | √ | √ | √ | |
impedance | unit:Ω,CT secondary measure secondary impedance | √ | √ | √ | √ | √ | √ | √ | √ | |
Resistance | resistance(25ºC) | unit:Ω,CT secondary measure secondary resistance | √ | √ | √ | √ | √ | √ | √ | √ |
resistance(75ºC) | unit:Ω,Convert to resistance under 75ºC | √ | √ | √ | √ | √ | √ | √ | √ | |
excitation | knee voltage and knee current | unit:V and A,According to standard definition,when knee voltage increase 10%,knee current increase 50%. | √ | √ | √ | √ | √ | √ | √ | √ |
Unsaturated inductance Lu | unit:H,The average inductance of linear section for excitation curve | √ | √ | √ | √ | √ | √ | √ | √ | |
remanence coefficient Kr | ratio of magnetism and magnetic | √ | √ | √ | √ | √ | √ | √ | √ | |
Second time constant Ts | unit:s,the time constant of CT's second connect rated burden | √ | √ | √ | √ | √ | √ | √ | √ | |
limiting e.m.f Eal | unit:V,calculation limit e.m.f. according to the CT nameplate and resistance under 75ºC | √ | √ | √ | √ | √ | √ | |||
composite error | limiting e.m.f or the composite error of rated knee potential | √ | √ | √ | √ | |||||
Peak transient error | Peak transient error of limiting e.m.f | √ | √ | √ | ||||||
ALF | actual ALF | √ | √ | |||||||
Instrument security coefficient | actual instrument security coefficient | √ | ||||||||
Symmetrical short-circuit current multiples Kssc | actual symmetrical short-circuit current multiples | √ | √ | √ | √ | |||||
transient dimensioning factor | actual transient dimensioning factor | √ | √ | √ | ||||||
calcuated coefficient Kx | actual calcuated coefficient | √ | ||||||||
Rated knee potential Ek | √ | |||||||||
Ie corresponding with Ek | The actual excitation current corresponding with rated knee potential | √ | ||||||||
Rated voltage Ual | The rated equivalent second limit voltage | √ | ||||||||
Ial corresponding with Ual | The actual excitation current corresponding with the rated equivalent second limit voltage | √ | ||||||||
Ratio | Ratio | Actual current ratio under rated burden | √ | √ | √ | √ | √ | √ | √ | √ |
Turns ratio | The ratio of actual secondary winding and primary winding | √ | √ | √ | √ | √ | √ | √ | √ | |
Ratio difference | The current errors under rated load | √ | √ | √ | √ | √ | √ | √ | √ | |
Phase difference | The D-value of phase under rated load | √ | √ | √ | √ | √ | √ | √ | √ | |
Polarity | There're two polarity relationship for primary CT and secondary CT: Positive and Negative | √ | √ | √ | √ | √ | √ | √ | √ | |
Turn ratio error | The relative error between measured trun ratio and rated turn ratio | √ | √ |
result | description | P | M | |
Resistance | resistance(25ºC)R | unit:Ω,resistance value under current temperature | √ | √ |
resistance(75ºC)Rref | unit:Ω,Resistance value under reference temperature(the temperature is variable) | √ | √ | |
excitation | knee voltage and knee current | unit:V and A,According to standard definition,when knee voltage increase 10%,knee current increase 50%. | √ | √ |
Ratio | Ratio | Actual current ratio under rated burden | √ | √ |
Turns ratio | The ratio of actual secondary winding and primary winding | √ | √ | |
Ratio difference | The current errors under rated load | √ | √ | |
Phase difference | The D-value of phase under rated load | √ | √ | |
Polarity | There're two polarity relationship for primary and secondary , Positive and Negative | √ | √ |
Sr no | Description | Qty |
1 | Host | 1 |
2 | Up-flow reactor(optional) | 1 |
3 | Power line | 1 |
4 | Red test line | 1 |
5 | Yellow test line | 1 |
6 | Green test line | 1 |
7 | High current test line(optional) | 2 |
8 | Control line(optional) | 1 |
9 | Ground wire | 1 |
10 | Alligator clip | 4 |
11 | Alligator clip | 2 |
12 | U type insert | 4 |
13 | Thermal printing paper | 4 |
14 | U disk | 1 |
15 | Protective tube | 5 |
16 | Special screwdriver for protective tube | 1 |
17 | Aluminum alloy packing box | |
18 | Calibration report | 1 |
19 | Operating manual | 1 |