Insulation Oil Tan Delta Tester/Insulation Oil Dielectric Loss Testing Device

Product Details
Customization: Available
After-sales Service: Life Time Maintenance
Warranty: One Year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Insulation Oil Tan Delta Tester/Insulation Oil Dielectric Loss Testing Device
  • Insulation Oil Tan Delta Tester/Insulation Oil Dielectric Loss Testing Device
  • Insulation Oil Tan Delta Tester/Insulation Oil Dielectric Loss Testing Device
  • Insulation Oil Tan Delta Tester/Insulation Oil Dielectric Loss Testing Device
  • Insulation Oil Tan Delta Tester/Insulation Oil Dielectric Loss Testing Device
  • Insulation Oil Tan Delta Tester/Insulation Oil Dielectric Loss Testing Device
Find Similar Products

Basic Info.

Model NO.
YJJ-608
Max Diameter of Workpiece
<500mm
Mass Scope of Workpiece
<900kg
Type
Universal Testing Machine
Maxcapacity
<1000KN
Accuracy Grade
1
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
LCD
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
10
Colour
Grey
Transport Package
Wooden Case
Specification
50*40*40
Trademark
GOLDSOL
Origin
Wuhan China
HS Code
9030332000
Production Capacity
20 Units

Packaging & Delivery

Package Size
40.00cm * 40.00cm * 50.00cm
Package Gross Weight
25.000kg

Product Description

Product overview
YJJ-608 Auto Oil C & Tan Delta Tester (Automatic oil dielectric loss and resistivity tester) is designed and manufactured according to GB / T5654-2007 measurement of relative permittivity, dielectric loss factor and DC resistivity of liquid insulating materials. It is used to measure the dielectric loss factor and DC resistivity of liquid insulating media such as insulating oil. Integrated structure. The main components such as dielectric loss oil cup, temperature controller, temperature sensor, dielectric loss test bridge, AC test power supply, standard capacitor, high resistance meter and DC high voltage source are integrated. The instrument adopts full digital technology, all intelligent and automatic measurement, and is equipped with large screen 5.7 inch TFT pure color LCD touch display and full chinese or english menu. The test results can be automatically stored and printed out. The operator can skillfully use it without professional training.

Insulation Oil Tan Delta Tester/Insulation Oil Dielectric Loss Testing DeviceInsulation Oil Tan Delta Tester/Insulation Oil Dielectric Loss Testing Device

Main functions and features
(1) Oil cup adopts the three electrode structure in accordance with the national standard GB / T5654-2007, and the electrode spacing is 2mm, which can eliminate the influence of stray capacitance and leakage on the dielectric loss test results.

(2) The instrument adopts medium frequency induction heating and PID temperature control algorithm. The heating method has the advantages of non-contact between oil cup and heating body, uniform heating, fast speed and convenient control, so that the temperature is strictly controlled within the preset temperature error range.

(3) The internal standard capacitor is SF6 gas filled three-point polar capacitor. The dielectric loss and capacitance of the capacitor are not affected by ambient temperature and humidity, so the accuracy of the instrument can still be guaranteed after long-term use.

(4) AC test power supply adopts AC-DC-AC conversion mode, which can effectively avoid the influence of voltage and frequency fluctuation on the accuracy of dielectric loss test. Even if the generator generates electricity, the instrument can operate correctly. (optional)

(5) Perfect protection function. When there is over-voltage, over-current, high-voltage short-circuit, the instrument can quickly cut off high-voltage, and send out a warning message. When the temperature sensor fails or is not connected, a warning message will be sent out.

(6) Built in temperature limiting relay in the medium frequency induction furnace. When temperature exceeds 120 ºC, the relay releases and the heating stops.

(7) Convenient setting test parameters. Temperature setting range: 0-120 ºC, AC  voltage setting range:200-2200V, and DC voltage setting range:0-500V.

(8) Large TFT color touch LCD, display clearly. With simple setup, the instrument can test automatically. The test results are stored and printed automatically.

(9) Real-time clock, test date and time can be saved, displayed and printed with test
results.

(10) Empty electrode cup calibration function. The capacitance and dielectric loss factor of the empty electrode cup are measured to judge the cleaning and assembly status of the empty electrode cup. The calibration data are automatically saved to facilitate the accurate calculation of relative permittivity and DC resistivity.

(11) The core of the instrument is RAM9 platform, with high precision and high
speed.

(12) Automatic oil discharge dielectric loss is for buyer's optional.
Insulation Oil Tan Delta Tester/Insulation Oil Dielectric Loss Testing Device
Conditions of use
1. Ambient temperature: 0ºC~40ºC
2. Relative humidity: < 75%

Vessel
 1) Oil Cup, High-voltage Terminal           
 2) Oil Gap   
 3) Inner Electrode, Testing Terminal   
 4) Fix Knob of Inner Electrodes
 5) Inner Electrode, Measuring Shielding Terminal          
 6) Testing Terminal
 7) Temperature Connector

Insulation Oil Tan Delta Tester/Insulation Oil Dielectric Loss Testing Device

Main technical indicators
1. Power supply voltage: AC 220 V ± 10%
2. Power frequency: 50 Hz / 60 Hz ± 1%
3. Measurement range: Capacitance: 5pF~200pF
     Relative permittivity: 1.000 ~ 30.000
     Dielectric loss factor: 0.00001-100
     DC resistivity: 2.5 mΩ m ~ 20 TΩ M
4. Measurement accuracy: Relative permittivity: ± (1-10)% reading
     Dielectric loss factor: ± (5% reading + 0.0002)
     DC resistivity: ± 10% reading
5. Resolution: Capacitance: 0.01pF
     Relative permittivity:0.001
     Dielectric loss factor: 0.00001
6. Temperature measurement range: 40~120 ºC
7. Temperature measurement error: ± 0.5 ºC
8. AC test voltage: 200 ~ 2200v, continuously adjustable, frequency: 50 Hz
9. DC test voltage: 0 ~ 500V continuously adjustable
10. Power consumption: 500W
11. Dimension: 460mm * 370mm * 330mm
12. Total weight: 25kg

Insulation Oil Tan Delta Tester/Insulation Oil Dielectric Loss Testing Device


Accessaries
Sr.no        Description       Quantity
 
  1 Stainless steel test vessel  1  unit
  2 Temperature control cable  1  unit
  3 Data acquisition cable  1  unit
  4 High voltage calbe (2KV)  1  unit
  5 Measuring cable  1  unit
  6 Power supply cable  1  unit
  7 Measuring cup  1  unit
  8 Printing paper  1  unit
  9 Power supply  1  unit
 10 Calibration report  1  unit
 11 Operating manual  1  unit

Insulation Oil Tan Delta Tester/Insulation Oil Dielectric Loss Testing Device

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier