Transformers Insulators Lightning Impulse Impact Generator

Product Details
Customization: Available
After-sales Service: Life Time Maintenance
Warranty: One Year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Transformers Insulators Lightning Impulse Impact Generator
  • Transformers Insulators Lightning Impulse Impact Generator
  • Transformers Insulators Lightning Impulse Impact Generator
  • Transformers Insulators Lightning Impulse Impact Generator
  • Transformers Insulators Lightning Impulse Impact Generator
  • Transformers Insulators Lightning Impulse Impact Generator
Find Similar Products

Basic Info.

Model NO.
DWCJ-300KV/15KJ
Mass Scope of Workpiece
900kg
Type
Universal Testing Machine
Maxcapacity
110
Accuracy Grade
1
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Control
Computer Control
Weight
100-500Kg
Power Source
AC220V
Oil Cylinder Position
Under
Transport Package
Wooden Case
Specification
1200mm*800mm
Trademark
GOLDSOL
Origin
Wuahn China
HS Code
903033200
Production Capacity
10 Units/Month

Packaging & Delivery

Package Size
120.00cm * 90.00cm * 170.00cm
Package Gross Weight
600.000kg

Product Description

Application
This lightning impulse voltage generator test system device is mainly suitable for testing Insulators,transformers, switches,Arresters and bushes with voltage levels  36kV for standard full lightning impulse voltage.


Woking condition:
1.Altitude≤2000m
2.Environment temperature: -15ºC~50ºC
3.Relative humidity≤90%
4.Installation place: indoor type, movable
5.Ground resistance<0.5Ω

Transformers Insulators Lightning Impulse Impact Generator

Transformers Insulators Lightning Impulse Impact Generator
Transformers Insulators Lightning Impulse Impact Generator

Test equipment included in the test system(Model: DWCJ-300KV/15KJ)
300KV/15KJ Full wave impulse device, 300kV Chopping device, 300KV Capacitive voltage divider, 100KV/50mA Rectifier Transformer, Measurement&control system(including Lighting impulse voltage Test Bench, TDS3012C Oscilloscope, IPM-24 Peak volmeter, 1 set Attenuator , printer, control&measurement software, etc.)

1. Impulse voltage generator (300kV/15kJ)
   1)Main technical parameters
   2)Nominal lightning impulse voltage: 300kV
   3)Nominal capacity (energy): 15kJ
   4)Number of stages/ Capacity per stage: 3 /5kJ
   5)Rated capacitance: 1.0μF 
   6)Voltage per stage: ± 100kV
   7)Output waveform:
   8)1.2±30%/50±20%μ S standard lightning impulse voltage full wave, oscillation amplitude at peak value≤5%
   9)Min. output voltage≤10 %Un
   10)Generator efficiency 90%;
    11)Triggering range:  20%
    12)Working Duration:
    13)continuous operation >70%Un, charge&discharge every 90s
    14)continuous operation <70%Un, charge&discharge every 60s
    15)Instability of output peak voltage≤1.0 %, the lowest output 10% of the nominal voltage of the device.
    16)Malfunction rate while synchronous discharge<2 %
    17)Ignition range: 10%~100%
    18)Chopping device can produce cut-off lightning wave with a cut-off time of 2 ~ 6 μ s, and the dispersion of the cut-off wave is less than 100ns.
    19)Base: 2.5m × 1.7m, caster moving.
    20)Height: About 1.5m. Weight: about 650kg
 
Transformers Insulators Lightning Impulse Impact Generator
2. Rectifier charging power supply
  1. Model No.: LGR-100/50
  2. Rated voltage:  Un = 100kV DC (Positive or negative polarity)
  3. Rated current:  In = 50mA (Under rated voltage)
  4. Voltage control: Controllable constant current charge, regulate range 0~100% Un
  5. Polarity conversion: Auto convert path of high voltage silicon stack
  6. Input voltage: 220V, single-phase
  7. Frequency: 50/60Hz
  8. Power supply capacity: 5kVA
  9. power supply resistance: 3 pcs
3. Low damping capacitive voltage divider
  1. Model: 300kV/300pF
  2. Rated voltage: 300kV
  3. Rated capacitance: 300pF
  4. Stage of capacitor: 1 stage
  5. Capacitance per stage: 300pF
  6. Square wave response: Partial response time is less than 100ns, overshoot is less than 20%
  7. Voltage division uncertainty: Less than 1%
Transformers Insulators Lightning Impulse Impact Generator
Transformers Insulators Lightning Impulse Impact Generator
Transformers Insulators Lightning Impulse Impact Generator

4. Chopping device (for option)
  1. Rated Voltage: 300kV
  2. Sphere gap type: Ф300mm
  3. Time delay mode: 2-6µs time delay adjustable circuit provide chopping trigger pulse.
  4. Chopping wave dispersibility: Chopping wave time standard error is less than 0.1µs.
  5. Sphere gap Qty: 2 pcs
  6. chooped wave resistance 1 pc
5. Controller (Signal analyze auto-testing system)
  1. Waveform test: TDS3012C digital oscilloscope
         Max. sample rate 1.0GS/s, 100MHz bandwidth, resolution 8bit
         Record length 2.5K byte, 2 channels
 
     2.Waveform analyzation:
        Industrial control computer and LCD display
        Impulse test software
        Display and calculate impulse waveform parameters
        Waveform comparison function
        Waveform amplification, shrink and translation
        Store and invoking of waveform
        Auto-generated test report in picture format

6. Accessories
  1. High performance 100 times specialized attenuator 2 pcs
  2. Isolation filter shielding design
  3. Wave head resistance 3 groups
  4. Wave tail resistance 3 groups
Transformers Insulators Lightning Impulse Impact Generator

7. Standard
  1. IEC 60060-1
  2. IEC 60076-3
  3. IEC 62271-1
  4. IEC 62271-200
  5. Test transformer (JB / T9641-1999)
  6. GB1094-2003 power transformer
  7. GB / t509-1997 power transformer test guide
  8. DL / t596 / 1996 code for preventive test of electric power equipment
  9. GB311.1-1997 insulation coordination of high voltage transmission and transformation equipment
  10. GB / t16927.1-1997 high voltage test technology general test requirements
  11. GB / T16927.2-1997 high voltage test technology measurement system Digital recorder for high voltage impulse test
  12. ZB F24 001-90 implementation rules for impulse voltage measurement
  13. GB191 packaging and transportation marks
  14. JB / t563 technical conditions for ordering coupling capacitors and capacitor voltage dividers
  15. GB4208 enclosure protection level
  16. GB813-89 oscilloscope and peak meter for impact test
  17. GB7449-87 test guide for lightning impulse and operation impulse of power transformers and reactors
  18. JB / T501 power transformer test guide
  19. Transformer test technology (JB / t501-1991)
  20. IEC60-1 and IEC60-2 high voltage test technology
  21. GB50150-91 standard for hand over test of electrical equipment in electrical equipment installation engineering
  22. DL / T557-94 high voltage line insulator steep wave impact test, definition, test method and criteria
  23. DL / T 848.5-2004 general specification for high voltage test equipment Part 5: impulse voltage generator
  24. DL / T 846.1-2003 general specification for high voltage test equipment Part 1: high voltage divider measurement system
  25. DL / T 846.2-2004 general specification for high voltage testing equipment Part 2: impulse voltage measuring system
Transformers Insulators Lightning Impulse Impact Generator
Transformers Insulators Lightning Impulse Impact Generator

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier