Wuhan Goldsol Co., Ltd.

Resonant Test Equipment, Resonant Testing Set, Hi-Pot Test Set manufacturer / supplier in China, offering Resonant Test Set, Vlf Hipot Tester 40kv, Power Frequency Withstand Voltage Tester 5kVA/100kv and so on.

Resonant Test Set

FOB Price: Get Latest Price
Min. Order: 1 Piece
Production Capacity: 20 Sets/Month
Transport Package: Plywood Case
Payment Terms: L/C, T/T

Basic Info.

Model NO.:RTSS-500KVA/500KV
Resonant Test Set:Resonant Test Set
Trademark:GOLDSOL
Specification:GB50150-2006
Origin:China
HS Code:8548900090

Product Description

The equipment is suitable for testing 220KV GIS Breaker, Cable, transformer or other apparatus.



Parameters of Full System

- Rated Capacity: 500kVA;
- Output Voltage: 0-500KV
- Max Output current: 1A;
- Output frequency: 30-300Hz;
- Input Power: 415V 3-phase, 50Hz
- Waveform distortion rate: Output voltage distortion ≤ 1%;
- Working time: Continuous 5 minutes under rated load; 1minute under overvloltage of 1.2times
- Working Temperature: -10~+40C
- Quality factors: Q ≥ 30 (f=45Hz);
- Stability: Over-current/over-voltage/Flashover protection; Auto Time; Touch Screen;
- Accuracy: RMS 1.5

System configuration and parameters

Controller 20kVA/400V, 1 unit
- Rated output capacity: 20kVA
- Power Supply: 380V ± 10% (single phase), 50Hz
- Output Voltage: 0 - 400V, single phase;
- Rated Output Current: 53A;
- Rated Input Current: 53A
- Output wave form: Sine wave
- Voltage Resolution: 0.01kV
- Voltage measurement accuracy: 1.0%
- Frequency: 20 - 300Hz
- Frequency resolution: ≤ 0.1Hz
- Frequency stability: 0.1%
- Noise level: ≤ 50dB
- Size: 38x40x50cm(Approx)
- Weight: About 25kgs




Excitation Transformer 2.5kV/15kv/30kV, 1 unit
- Rated capacity: 20kVA;
- Input voltage: 400V, single phase;
- Output voltage: 15kv; 30kV;
- Frequency: 30-300Hz;
- Structure: Dry Transformer,
- Size: 30x35x55cm (Approx)
- Weight: About 130kg;

Fixed Reactor 50kVA/50KV (9 parts), 9 units
- Rated Capacity: 50kVA;
- Rated voltage: 50kV;
- Rated current: 1A;
- Induction: 180H/each part
- Quality factor: Q ≥ 30 (f=45Hz);
- Structure: Dry Transformer
- Size: Height of 0.5m/each (Approx)
- Weight: 55kgs/each;

Variable Reactor 50kVA/50KV (1 part), 1 unit
- Rated Capacity: 50kVA;
- Rated voltage: 50kV;
- Rated current: 1A;
- Variable Induction: 150H-250;
- Quality factor: Q ≥ 40;
- Structure: Dry Transformer, iron core with adjustable;
- Size: Height of 1.5m *0.6m(Approx)
- Weight: 100kgs;

5)High Voltage Divider 500kV -500pF, 1 unit
- Rated voltage: 500KV
- High-voltage capacitance: 500pF
- Frequency: 30-300Hz
- Dielectric loss: Tgσ ≤ 0.5%;
- Divider ratio: 1000: 1
- Accuracy: RMS 1.0;
- Size: Height of 1.5m
- Weight: About 25kg;
  Ctn  No.    Name  of  Commodity     Qty  G. W(kg)  N. W(kg)      Size(mm)
No. 1-1  Controller, 20kW/380V    1  case  @45  @28610*490*640 
No. 2-2  Excitation  Transformer    1  case  @194  @150590*560*720 
No. 3-11  Fixed  Reactor     9  cases  @66/594  @50/450470*460*640 
No. 12-12  Variable  Reactor    1  case  @68/  @52470*460*640 
No. 13-13  Capacitive  Divider    1  case  @70  @451260*870*450 
No. 14-14  Supporting  Frame    1  case  @200  @1502060*630*740 
No. 15-15  Equipotential  Shielding,   Φ 1000    1  case  @100  @751020*1100*1110 
No. 16-16  Equipotential  Shielding,   Φ 800    1  case  @35  @20900*910*490 
                         
                                                              Total

  16  cases

  1306kgs

  970kgs

      4.89cbm
Send your message to this supplier
Avatar
Mr. Luo