Wuhan Goldsol Co., Ltd.

Remote High Voltage Detector, Remote High Voltage Electrical Field Detector, High Voltage Live Line Detector manufacturer / supplier in China, offering Remote High Voltage Field Detector, Vlf Cable Testing 90V, Power Frequency Withstand Voltage Tester 5kVA/100kv and so on.

Supplier Homepage Product List Others Remote High Voltage Field Detector

Remote High Voltage Field Detector

FOB Price: Get Latest Price
Min. Order: 1 Piece
Payment Terms: T/T, Paypal

Basic Info.

Model NO.:TAG-8600
Live Line Detector:Live Line Detector

Product Description

I. Intruduction
TAG-8600 High voltage detector 220KV, which is suitable for testing 6KV to 220KV live transmission line, phase tests and phase sequence tests for substations, with functions of phase testing, phase sequence testing, electrical inspection. With strong anti-interference ability, in line with (EMC ) standards, adapt to a variety of electromagnetic interference occasions. High voltage phase signal will be taken out by the collector, discharge directly after treatment. Received by instrument and compare the phase, and identify the results. This product is wireless transmission, safe, reliable, fast and accurate, adapt to a variety of phase testing occasions. Its main advantage is without the wire which connect two grids (power source) , distance up to 200M and could trough enclosure or partition plate, improve the safety, without the limitation by terrain and the structure of the equipment , easy to operate, only need one person to operate and one person to supervise.
 
II. Safety
1.When testing at field, keep a safe distance as per high-voltage power sector standard operation.
2. It has standard configuration of insulating rod 3 m, corresponding to the voltage class ≤ 220kV,
please use insulated rod lengths greater than 3 meters if line voltage higher than 220KV.
3.When phase clarification operating, holder should not exceed insulated rod handle.
 
III. Advantage
1. Use high capacitive non-maintenance lithium battery to supply power, special for field test.
2. Long transmission distance, up to 200M. 
3. LCD display phase ,waveform, frequency , safe and reliable.
4. Telescopic insulation bar, easy to use.
5. Portable receiver with non-skid treatment.
6. uses advanced technique, small in volume, light in weight 
 
IV. Technical Parameter
1.Phase error : ≤5 °.
2.Frequency accuracy: ± 0.1Hz.
3.Measuring voltage class: 6KV~220KV.
4.Transmission distance between the transmitter and Receiver: > 130 m;
  Maximum distance between 2 transmitters: 260 meters.
5.A class judgment result (in-phase, out-phase):
  phase difference ≥30°: out of phase;  
  phase difference <30°: in-phase.
6.Live voice prompt, Boy"in-phase" and Girl "out of phase".
7.LCD simultaneously displays 2 lines' phase, frequency, waveform and vector diagram.
8.Receiver (host) shows battery level, and automatic shutdown if no operating in a half hour.
9.Transmitter and receiver are built-in rechargeable lithium battery.
10.High voltage electrical detection and approval phase sequence dual purposes.
11.Leakage current when HV measurement: <10µA.
12.Transmitter operating power <0.1W, Receiving operating power <0.3W.
13.Receiver lithium battery capacity:2200mAH, transmitter battery capacity:350mAH.
14.Operating environment: -35ºC ~ + 45 ºC, humidity ≤95% RH.
15.Storage environment: -40ºC ~ + 55 ºC, humidity ≤95% RH.
16.Weight: about 5KG.
17.Package dimension: length 71cm * width 26cmm * height 11cm.
 
 
V. Additional remark
Vlotage ClassOperating remarkRemark
500KVConnected Transmitters to Insulation rod(5m), hooking HV line,start the receiverNormal
330KVConnected Transmitters to Insulation rod(4m), hooking HV line,start the receiverNormal
220KVConnected Transmitters to Insulation rod(3m), hooking HV line,start the receiverNormal
110KVConnected Transmitters to Insulation rod(3m), hooking HV line,start the receiverNormal
35KVConnected Transmitters to Insulation rod(3m), hooking HV line,start the receiverNormal
10KV(Naked)Connected Transmitters to Insulation rod(3m), hooking HV line,start the receiverNormal
10KV(with insulation cover)Connected Transmitters to Insulation rod(3m), hooking HV line,start the receiverTurn on the transmitter, off the transmitter after finishing
380V/220VConnected commercial power special line to Transmitters,start the receiverUsing commercial power special line
Switch induction 
(~5V)
Connected switch inductive cable to the transmitters and start the receiverUsing switch inductive power cable
 
VI. Accessaries
Sr no.DescriptionQuantity
  1Aluminium alloy box1 unit
  2Receiver (Host)1 unit
  3Transmitter2 units(X,Y, each one)
  4Extension-type insulation road(3m)2 units
  5Charger2 units
  6Pointed end2 units
  7Commercial power special cable2 units
  8Switch inductive power cable2 unis (Optional)
  9Operating manaul1 unit
  10Calibration1 unit
 
 
 
 
Send your message to this supplier
Avatar
Mr. Luo
Manager
*From
To Mr. Luo
*Message
Enter between 20 to 4,000 characters.
This is not what you are looking for? Post a Sourcing Request Now
Find Similar Products By Category:

Wuhan Goldsol Co., Ltd.

- Hubei, China
- Manufacturer/Factory, Trading Company

Gold Member Since 2012
Audited Supplier
  • Spanish / French / Portuguese / Russian Speaker